Abstract

The derivation of an efficient operational strategy for storing intermittent renewable energies using a hybrid battery-hydrogen energy storage system is a difficult task. One approach for deriving an efficient operational strategy is using mathematical optimization in the context of model predictive control. However, mathematical optimization derives an operational strategy based on a non-exact mathematical system representation for a specified prediction horizon to optimize a specified target. Thus, the resulting operational strategies can vary depending on the optimization settings. This work focuses on evaluating potential improvements in the operational strategy for a hybrid battery-hydrogen energy storage system using mathematical optimization. To investigate the operation, a simulation model of a hybrid energy storage system and a tailor-made mixed integer linear programming optimization model of this specific system are utilized in the context of a model predictive control framework. The resulting operational strategies for different settings of the model predictive control framework are compared to a rule-based controller to show the potential benefits of model predictive control compared to a conventional approach. Furthermore, an in-depth analysis of different factors that impact the effectiveness of the model predictive controller is done. Therefore, a sensitivity analysis of the effect of different electricity demands and resource sizes on the performance relative to a rule-based controller is conducted. The model predictive controller reduced the energy consumption by at least 3.9 % and up to 17.9% compared to a rule-based controller. Finally, Pareto fronts for multi-objective optimizations with different prediction and control horizons are derived and compared to the results of a rule-based controller. A cost reduction of up to 47 % is achieved by a model predictive controller with a prediction horizon of 7 days and perfect foresight.

Authors 3

  1. Alexander Holtwerth corresponding

    Forschungszentrum Jülich

    Affiliation as printed

    Institute of Energy and Climate Research - Energy Systems Engineering (IEK-10), Forschungszentrum Jülich GmbH, Wilhelm-Johnen-Straße, Jülich, 52428, Germany

  2. Forschungszentrum Jülich

    Affiliation as printed

    Institute of Energy and Climate Research - Energy Systems Engineering (IEK-10), Forschungszentrum Jülich GmbH, Wilhelm-Johnen-Straße, Jülich, 52428, Germany

  3. RWTH Aachen University · Forschungszentrum Jülich

    Affiliation as printed

    Institute for Energy Efficient Buildings and Indoor Climate, E.ON Energy Research Center, RWTH Aachen University, Mathieustraße 10, Aachen, 52074, Germany

    Institute of Energy and Climate Research - Energy Systems Engineering (IEK-10), Forschungszentrum Jülich GmbH, Wilhelm-Johnen-Straße, Jülich, 52428, Germany

Cited by 28 stored of 28

No patents citing this paper on Lens.org (checked 2026-10-06).

References 52