Abstract
Three-dimensional (3D) full-field measurements provide a comprehensive and accurate validation of finite element (FE) models. For the validation, the result of the model and measurements are compared based on two respective point-sets and this requires the point-sets to be registered in one coordinate system. Point-set registration is a non-convex optimization problem that has widely been solved by the ordinary iterative closest point algorithm. However, this approach necessitates a good initialization without which it easily returns a local optimum, i.e. an erroneous registration. The globally optimal iterative closest point (Go-ICP) algorithm has overcome this drawback and forms the basis for the presented open-source tool that can be used for the validation of FE models using 3D full-field measurements. The capability of the tool is demonstrated using an application example from the field of biomechanics. Methodological problems that arise in real-world data and the respective implemented solution approaches are discussed.
Authors 5
-
Affiliation as printed
Institute of Bioengineering, FH Aachen University of Applied Sciences, Heinrich-Mußmann Straße 1, 52428 Jülich, Germany
-
University of Oxford · FH Aachen
Affiliation as printed
Institute of Bioengineering, FH Aachen University of Applied Sciences, Heinrich-Mußmann Straße 1, 52428 Jülich, Germany; Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Windmill Road, Oxford OX3 7LD, United Kingdom
Institute of Bioengineering, FH Aachen University of Applied Sciences, Heinrich-Mußmann Straße 1, 52428 Jülich, Germany
Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Windmill Road, Oxford OX3 7LD, United Kingdom
-
Affiliation as printed
Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Windmill Road, Oxford OX3 7LD, United Kingdom
-
Affiliation as printed
Institute of Bioengineering, FH Aachen University of Applied Sciences, Heinrich-Mußmann Straße 1, 52428 Jülich, Germany
-
University of Oxford · FH Aachen
Affiliation as printed
Institute of Bioengineering, FH Aachen University of Applied Sciences, Heinrich-Mußmann Straße 1, 52428 Jülich, Germany; Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Windmill Road, Oxford OX3 7LD, United Kingdom. Electronic address: a.jung@fh-aachen.de
Institute of Bioengineering, FH Aachen University of Applied Sciences, Heinrich-Mußmann Straße 1, 52428 Jülich, Germany
Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Windmill Road, Oxford OX3 7LD, United Kingdom
Cited by 2 stored of 2
2 results
No patents citing this paper on Lens.org (checked 2026-10-06).