Brain Tumor Characterization Using Multiple MR Parameters From Multi‐Contrast EPI With Keyhole ( GE ‐ SE EPIK ) Including Oxygen Extraction Fraction: A Comparison to O‐(2‐[ 18F ]Fluoroethyl)‐L‐Tyrosine (FET) Positron Emission Tomography

Journal of Magnetic Resonance Imaging, vol. 62, pp. 721–736

Abstract

ABSTRACT Background Tumor characterization and treatment efficacy are associated with tissue hypoxia. MR‐derived oxygen extraction fraction (OEF) may offer valuable tumor insights but depends on multiple measurement parameters, often requiring multiple sequence acquisitions. Specific multi‐parametric sequences offer direct access to MR parameter sets within short acquisition times. Purpose To evaluate the potential of gradient‐echo spin‐echo echo‐planar imaging with keyhole (GE‐SE EPIK)‐derived parameters (OEF/T2/T2*/venous cerebral blood volume (vCBV)) to characterize increased metabolic activity tissue identified in [18F]fluoroethyl‐L‐tyrosine (FET) PET, serving as a surrogate for neoplastic tissue. Study Type Retrospective. Population Fifty‐seven brain tumor patients (female/male:31/26; age 27–73 years) with 66 histologically confirmed lesions (suspected glioblastoma (16), glioblastoma (28), astrocytoma (11), metastasis (6), oligodendroglioma (5)). Field Strength/Sequence 10‐echo GE‐SE EPIK sequence at 3 T. Assessment GE‐SE EPIK data were acquired in a hybrid MR PET scanner during FET PET acquisitions. Two tumor segmentations based on FET‐PET uptake and FLAIR hyperintensities were manually created. Mean GE‐SE EPIK‐derived parameters were calculated within tumor regions and compared to contralateral reference values. Relative tumor‐to‐reference parameters were compared across tumor types. Statistical Tests One/two‐sampled, two‐tailed t‐tests of mean relative MR‐derived parameters. p‐value < 0.05 was considered significant. Results Significantly increased T2/T2* and decreased vCBV/OEF were found in FET‐PET and FLAIR‐derived VOIs. Latter showed decreased R2′. Significant correlation between FET uptake and T2/T2* was found in FET‐VOIs (Pearson correlation: 0.26/0.31, respectively). Oligodendrogliomas showed significant differences to glioblastomas (rR2′, rOEF) and astrocytomas (rR2′). Metastasis showed different rT2 values than suspected gliomas. Astrocytoma differed from gliomas in FET‐TBR. Susceptibility artifacts in T2* maps from air‐tissue interfaces limited qualitative data interpretation. Data Conclusion GE‐SE EPIK provides multiple MR parameters that are sensitive to expected changes in tumor regions obtained from FET and FLAIR thresholds. Susceptibility artifacts in T2*/OEF maps made the differentiation between tumor relapse and treatment‐related changes challenging. However, certain MR‐derived parameters showed the ability to distinguish tumor types. Evidence Level 3. Technical Efficacy Stage 2.

Authors 11

  1. Forschungszentrum Jülich

    Affiliation as printed

    Institute of Neuroscience and Medicine 4 Forschungszentrum Jülich Jülich Germany

  2. Forschungszentrum Jülich · Maastricht University

    Affiliation as printed

    Cardiovascular Research Institute Maastricht (CARIM) Maastricht University Maastricht the Netherlands

    Institute of Neuroscience and Medicine 4 Forschungszentrum Jülich Jülich Germany

  3. Forschungszentrum Jülich

    Affiliation as printed

    Institute of Neuroscience and Medicine 4 Forschungszentrum Jülich Jülich Germany

  4. Forschungszentrum Jülich

    Affiliation as printed

    Institute of Neuroscience and Medicine 4 Forschungszentrum Jülich Jülich Germany

  5. Forschungszentrum Jülich · Universitätsklinikum Aachen · RWTH Aachen University

    Affiliation as printed

    Department of Nuclear Medicine RWTH Aachen University Hospital Aachen Germany

    Institute of Neuroscience and Medicine 4 Forschungszentrum Jülich Jülich Germany

  6. Forschungszentrum Jülich · University Hospital Cologne

    Affiliation as printed

    Center of Integrated Oncology Aachen Bonn Cologne Duesseldorf (CIO ABCD) Bonn Germany

    Department of Neurology Faculty of Medicine and University Hospital Cologne Cologne Germany

    Institute of Neuroscience and Medicine 3 Forschungszentrum Jülich Jülich Germany

  7. Maastricht University Medical Centre · Maastricht University · Universitätsklinikum Aachen · RWTH Aachen University

    Affiliation as printed

    Department of Nuclear Medicine RWTH Aachen University Hospital Aachen Germany

    Department of Radiology and Nuclear Medicine Maastricht University Medical Center (MUMC+) Maastricht the Netherlands

  8. Maastricht University Medical Centre · Maastricht University

    Affiliation as printed

    Cardiovascular Research Institute Maastricht (CARIM) Maastricht University Maastricht the Netherlands

    Department of Radiology and Nuclear Medicine Maastricht University Medical Center (MUMC+) Maastricht the Netherlands

  9. Forschungszentrum Jülich · Universitätsklinikum Aachen · RWTH Aachen University

    Affiliation as printed

    Department of Nuclear Medicine RWTH Aachen University Hospital Aachen Germany

    Institute of Neuroscience and Medicine 4 Forschungszentrum Jülich Jülich Germany

  10. Philipp Lohmann corresponding

    Forschungszentrum Jülich

    Affiliation as printed

    Institute of Neuroscience and Medicine 4 Forschungszentrum Jülich Jülich Germany

  11. Forschungszentrum Jülich · Universitätsklinikum Aachen · Jülich Aachen Research Alliance · RWTH Aachen University

    Affiliation as printed

    Department of Neurology RWTH Aachen University Hospital Aachen Germany

    Institute of Neuroscience and Medicine 11 Forschungszentrum Jülich Jülich Germany

    Institute of Neuroscience and Medicine 4 Forschungszentrum Jülich Jülich Germany

    JARA—BRAIN—Translational Medicine Aachen Germany

Cited by 1 stored of 1

1 result

No patents citing this paper on Lens.org (checked 2026-10-06).

References 53