A

The ‘Radiant Effect’: Recent Sonographic Image-Enhancing Technique and Its Impact on Nuchal Translucency Measurements

Preprints.org

Abstract

Background: This study assesses the effects of the ‘Radiant’ image enhancement technique on fetal nuchal translucency (NT) measurements during first trimester sonographic ex-ams. Methods: A retrospective analysis of 263 ultrasound images of first trimester midsagittal sections was conducted. NT measurements were obtained using a semi-automatic tool. Statistical methods were applied to compare NT measurements with and without ‘Radi-ant’ enhancement. An in-vitro setup with predefined line distances provided additional data. Results: Incremental increases in NT measurements were observed with varying levels of ‘Radiant’ application: An average increase of 0.19 mm with ‘Radiant min’, 0.24 mm with ‘Radiant mid’ and 0.30 mm with ‘Radiant max.’ The in-vitro results supported these findings, showing consistent effects on line thickness and measurement accuracy, with the smallest mean deviation occurring at the ‘Radiant mid’ setting. Conclusions: ‘Radiant’ image enhancement leads to significant increases in NT measure-ments. To avoid systematic biases in clinical assessments, it is advisable to disable ‘Radi-ant’ during NT measurement procedures. Further studies are necessary to corroborate these findings and to consider updates to the NT reference tables based on this technology.

Authors 6

  1. Arne Bergsch corresponding
    Affiliation as printed

    Praenatal plus Centre for Prenatal Diagnostics and Genetics ; Cologne , Germany

    Praenatal plus Centre for Prenatal Diagnostics and Genetics; Cologne, Germany

  2. J Degenhardt corresponding
    Affiliation as printed

    Praenatal plus Centre for Prenatal Diagnostics and Genetics ; Cologne , Germany

    Praenatal plus Centre for Prenatal Diagnostics and Genetics; Cologne, Germany

  3. Affiliation as printed

    Praenatal plus Centre for Prenatal Diagnostics and Genetics ; Cologne , Germany

    Praenatal plus Centre for Prenatal Diagnostics and Genetics; Cologne, Germany

  4. Deutsche Gesellschaft für Ultraschall in der Medizin

    Affiliation as printed

    DEGUM Arbeitskreis Ultraschallsysteme ;

    DEGUM Arbeitskreis Ultraschallsysteme;

  5. RWTH Aachen University

    Affiliation as printed

    RWTH Aachen University , Department of Gynecology and Obstetrics ; Aachen , Germany

    RWTH Aachen University, Department of Gynecology and Obstetrics; Aachen, Germany

  6. Affiliation as printed

    Praenatal plus Centre for Prenatal Diagnostics and Genetics ; Cologne , Germany

    Praenatal plus Centre for Prenatal Diagnostics and Genetics; Cologne, Germany

Cited by 1 stored of 1

1 result

No patents citing this paper on Lens.org (checked 2026-10-06).

References 8

8 results