A

Transient magnesium‐based thin‐film temperature sensor on a flexible, bioabsorbable substrate for future medical applications

Applied Research, vol. 3

Abstract

Abstract In this work, the bioabsorbable materials, namely fibroin, polylactide acid (PLA), magnesium, and magnesium oxide are investigated for their application as transient, resistive temperature detectors (RTD). For this purpose, a thin‐film magnesium‐based meander‐like electrode is deposited onto a flexible, bioabsorbable substrate (fibroin or PLA) and encapsulated (passivated) by additional magnesium oxide layers on top and below the magnesium‐based electrode. The morphology of different layered RTDs is analyzed by scanning electron microscopy. The sensor performance and lifetime of the RTD is characterized both under ambient atmospheric conditions between 30°C and 43°C, and wet tissue‐like conditions with a constant temperature regime of 37°C. The latter triggers the degradation process of the magnesium‐based layers. The 3‐layers RTDs on a PLA substrate could achieve a lifetime of 8.5 h. These sensors also show the best sensor performance under ambient atmospheric conditions with a mean sensitivity of 0.48 Ω/°C ± 0.01 Ω/°C.

Authors 6

  1. Philipps University of Marburg · FH Aachen

    Affiliation as printed

    Institute for Pharmaceutical Chemistry Philips University of Marburg Marburg Germany

    Institute of Nano‐ and Biotechnologies (INB), FH Aachen Jülich Germany

    Institute for Pharmaceutical Chemistry, Philips University of Marburg, Marburg, 35032 Germany

  2. FH Aachen

    Affiliation as printed

    Institute of Nano‐ and Biotechnologies (INB), FH Aachen Jülich Germany

  3. Affiliation as printed

    Fibrothelium GmbH Aachen Germany

    Fibrothelium GmbH, Aachen, 52068 Germany

  4. Affiliation as printed

    Fibrothelium GmbH Aachen Germany

    Fibrothelium GmbH, Aachen, 52068 Germany

  5. Philipps University of Marburg

    Affiliation as printed

    Institute for Pharmaceutical Chemistry Philips University of Marburg Marburg Germany

    Institute for Pharmaceutical Chemistry, Philips University of Marburg, Marburg, 35032 Germany

  6. Forschungszentrum Jülich · FH Aachen

    Affiliation as printed

    Institute of Biological Information Processing (IBI‐3), Forschungszentrum Jülich GmbH Jülich Germany

    Institute of Nano‐ and Biotechnologies (INB), FH Aachen Jülich Germany

Cited by 7 stored of 7

7 results

No patents citing this paper on Lens.org (checked 2026-10-06).

References 64