Abstract
Radiostereometric analysis (RSA) is an accurate and precise radiographic method that can be used to measure micromotion of implants and study joint kinematics in vivo. A calibration cage with radiopaque markers is used to calibrate the RSA images; however, the thickness (250 mm) of the calibration cage restricts the available area for the patient and equipment during RSA recordings. A thinner calibration cage would increase the recording area, facilitate handling of the cage, and ease integration of the cage with the RSA system. We developed a thinner calibration cage without compromise of accuracy and precision. First, we performed numerical simulations of an RSA system, and showed that the calibration cage thickness could be decreased to 140 mm maintaining accuracy and precision using 40 fiducial and 30 control markers. Second, we constructed a new calibration cage (NRT cage) according to the simulation results. Third, we validated the new calibration cage against two state-of-the-art calibration cages (Umeaa cage and Leiden cage) in a phantom study. All cages performed similar for marker-based analysis, except for y-rotation, where the Umeaa cage (SD = 0.064 mm) was less precise compared to the NRT (SD = 0.038 mm) and Leiden cages (0.042 mm) (p = .01). For model-based analysis the NRT cage had superior precision for translations (SD ≤ 0.054 mm) over the Leiden cage (SD ≤ 0.118 mm) and Umeaa cage (SD ≤ 0.093 mm) (p < .01). The combined study confirmed that the new and thinner calibration cage maintained accuracy and precision at the level of existing thicker calibration cages.
Authors 7
-
Jonathan Hugo Jürgens‐Lahnstein corresponding
Affiliation as printed
Department of Clinical Medicine Aarhus University Aarhus Denmark
Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
-
Aarhus University · Aarhus University Hospital
Affiliation as printed
Department of Clinical Medicine Aarhus University Aarhus Denmark
Department of Orthopaedics Aarhus University Hospital Aarhus Denmark
Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
Department of Orthopaedics, Aarhus University Hospital, Aarhus, Denmark
-
Affiliation as printed
Department of Orthopaedics Aalborg University Hospital Aalborg Denmark
Department of Orthopaedics, Aalborg University Hospital, Aalborg, Denmark
-
Affiliation as printed
Research and Development Engineer, NRT X‐RAY A/S Hasselager Denmark
Research and Development Engineer, NRT X-RAY A/S, Hasselager, Denmark
-
Bart L. Kaptein Aachen Department of Orthopaedics Leiden University Medical Center (LUMC) Leiden The Netherlands Department of Orthopaedics, Leiden University Medical Center
Leiden University Medical Center
Affiliation as printed
Department of Orthopaedics Leiden University Medical Center Leiden The Netherlands
Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands
-
Affiliation as printed
Department of Radiology Aarhus University Hospital Aarhus Denmark
Department of Radiology, Aarhus University Hospital, Aarhus, Denmark
-
Aarhus University · Aarhus University Hospital
Affiliation as printed
Department of Clinical Medicine Aarhus University Aarhus Denmark
Department of Orthopaedics Aarhus University Hospital Aarhus Denmark
Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
Department of Orthopaedics, Aarhus University Hospital, Aarhus, Denmark
Cited by 6 stored of 6
6 results
No patents citing this paper on Lens.org (checked 2026-10-11).