A

Development, construction, and validation of a thinner uniplanar calibration cage for radiostereometry

Journal of Orthopaedic Research®, vol. 40, pp. 1645–1653

Abstract

Radiostereometric analysis (RSA) is an accurate and precise radiographic method that can be used to measure micromotion of implants and study joint kinematics in vivo. A calibration cage with radiopaque markers is used to calibrate the RSA images; however, the thickness (250 mm) of the calibration cage restricts the available area for the patient and equipment during RSA recordings. A thinner calibration cage would increase the recording area, facilitate handling of the cage, and ease integration of the cage with the RSA system. We developed a thinner calibration cage without compromise of accuracy and precision. First, we performed numerical simulations of an RSA system, and showed that the calibration cage thickness could be decreased to 140 mm maintaining accuracy and precision using 40 fiducial and 30 control markers. Second, we constructed a new calibration cage (NRT cage) according to the simulation results. Third, we validated the new calibration cage against two state-of-the-art calibration cages (Umeaa cage and Leiden cage) in a phantom study. All cages performed similar for marker-based analysis, except for y-rotation, where the Umeaa cage (SD = 0.064 mm) was less precise compared to the NRT (SD = 0.038 mm) and Leiden cages (0.042 mm) (p = .01). For model-based analysis the NRT cage had superior precision for translations (SD ≤ 0.054 mm) over the Leiden cage (SD ≤ 0.118 mm) and Umeaa cage (SD ≤ 0.093 mm) (p < .01). The combined study confirmed that the new and thinner calibration cage maintained accuracy and precision at the level of existing thicker calibration cages.

Authors 7

  1. Aarhus University

    Affiliation as printed

    Department of Clinical Medicine Aarhus University Aarhus Denmark

    Department of Clinical Medicine, Aarhus University, Aarhus, Denmark

  2. Aarhus University · Aarhus University Hospital

    Affiliation as printed

    Department of Clinical Medicine Aarhus University Aarhus Denmark

    Department of Orthopaedics Aarhus University Hospital Aarhus Denmark

    Department of Clinical Medicine, Aarhus University, Aarhus, Denmark

    Department of Orthopaedics, Aarhus University Hospital, Aarhus, Denmark

  3. Aalborg University Hospital

    Affiliation as printed

    Department of Orthopaedics Aalborg University Hospital Aalborg Denmark

    Department of Orthopaedics, Aalborg University Hospital, Aalborg, Denmark

  4. Affiliation as printed

    Research and Development Engineer, NRT X‐RAY A/S Hasselager Denmark

    Research and Development Engineer, NRT X-RAY A/S, Hasselager, Denmark

  5. Leiden University Medical Center

    Affiliation as printed

    Department of Orthopaedics Leiden University Medical Center Leiden The Netherlands

    Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands

  6. Aarhus University Hospital

    Affiliation as printed

    Department of Radiology Aarhus University Hospital Aarhus Denmark

    Department of Radiology, Aarhus University Hospital, Aarhus, Denmark

  7. Aarhus University · Aarhus University Hospital

    Affiliation as printed

    Department of Clinical Medicine Aarhus University Aarhus Denmark

    Department of Orthopaedics Aarhus University Hospital Aarhus Denmark

    Department of Clinical Medicine, Aarhus University, Aarhus, Denmark

    Department of Orthopaedics, Aarhus University Hospital, Aarhus, Denmark

Cited by 6 stored of 6

6 results

No patents citing this paper on Lens.org (checked 2026-10-11).

References 35