Abstract

Frequency Mixing Magnetic Detection (FMMD) enables magnetic biosensing by probing the nonlinear dynamic response of magnetic nanoparticles (MNPs) under dual-frequency (f1, f2) excitation.Known Brownian-relaxation dominated MNPs BNF-Dextran 80 nm were studied in media with varying viscosities.The complex signal components at the mixing harmonics 𝑓 1 + 2 • 𝑓 2 and 𝑓 1 + 4 • 𝑓 2 were analyzed as a function of the low frequency excitation field, and the harmonic ratio 𝑅 = 𝐴 (𝑓 1 +2𝑓 2 ) /𝐴 (𝑓 1 +4𝑓 2 ) was evaluated as a sensitive metric.The measured ratios show a pronounced dependency on viscosity and field amplitude.The complex-plane trajectories additionally reveal viscosity-dependent changes in both amplitude and phase.These findings show that harmonic-ratio analysis in FMMD can provide environment-sensitive readout beyond conventional single-harmonic amplitude detection.The approach is therefore promising for viscosity-sensitive biosensing, where target binding or matrix changes modify the local hydrodynamic environment of the MNPs.

Authors 7

  1. Forschungszentrum Jülich

    Affiliation as printed

    Institute of Biological Information Processing , Bioelectronics (IBI-3) , Forschungszentrum Jülich , 52425 Jülich , Germany,

  2. Forschungszentrum Jülich

    Affiliation as printed

    Institute of Biological Information Processing , Bioelectronics (IBI-3) , Forschungszentrum Jülich , 52425 Jülich , Germany,

  3. Forschungszentrum Jülich

    Affiliation as printed

    Institute of Biological Information Processing , Bioelectronics (IBI-3) , Forschungszentrum Jülich , 52425 Jülich , Germany,

  4. FH Aachen · Forschungszentrum Jülich

    Affiliation as printed

    Institute of Biological Information Processing , Bioelectronics (IBI-3) , Forschungszentrum Jülich , 52425 Jülich , Germany,

    Medical Engineering and Applied Mathematics , FH Aachen University of Applied Sciences , 52428 Jülich , Germany

  5. University of Bonn

    Affiliation as printed

    Institute of Epileptology and Cognition Research , Sensory Dynamics and Behavior Lab , University of Bonn , Faculty of Medicine , 53127 Bonn ,

  6. FH Aachen

    Affiliation as printed

    Medical Engineering and Applied Mathematics , FH Aachen University of Applied Sciences , 52428 Jülich , Germany

Cited by 0 stored of 0

No patents citing this paper on Lens.org (checked 2026-10-11).

References 0