Demographic Shortcuts Account for Most of the Apparent Accuracy of Four-Class Gait-Based Differential Diagnosis in Neurodegenerative Disease: An Interpretability-Driven Audit of Machine Learning on a Public Gait Benchmark
Bioengineering, vol. 13, pp. 1092
Abstract
Machine-learning gait studies often report high accuracy for separating neurodegenerative diseases, but rarely test whether this reflects pathology or the demographic differences that accompany disease in convenience cohorts. We audited the PhysioNet Gait in Neurodegenerative Disease Database (63 subjects: controls, Parkinson’s disease [PD], Huntington’s disease [HD], amyotrophic lateral sclerosis [ALS]), classifying 37 stride-rhythm features under subject-disjoint nested leave-one-subject-out cross-validation. A random forest reached a macro-averaged one-vs-rest AUROC of 0.832 (95% CI 0.759–0.904; permutation p = 0.001). Four complementary audits—demographic-only baselines, confound adjustment, feature-family ablation, and age matching—show that this overstates gait-specific discrimination: five anthropometric variables alone reached an AUROC of 0.812, statistically indistinguishable from the gait model (p = 0.701), and the de-confounded gait model (0.755) fell further to 0.585 once age was matched across groups. HD was the exception, essentially unaffected by adjustment (0.812 → 0.804) and carried by variability and long-range-correlation measures. In an independent, age-matched cohort recorded with a different sensor (n = 110, PD versus control only), the same vulnerability reappeared through a different variable: the gait model (0.828) showed no statistically significant difference from walking speed alone (0.746, p = 0.11), while age and anthropometry fell to chance; this cohort contained no HD subjects, so the HD finding remains externally unvalidated. The shortcut vulnerability generalises across cohorts; the demographic variable that drives it does not. Four-class differential diagnosis is not demonstrated on this benchmark; HD gait arrhythmicity is the one signal that withstands internal sensitivity analysis. We recommend that accuracy claims from small, demographically imbalanced gait cohorts be accompanied by this kind of audit.
Authors 3
-
RWTH Aachen University · Universitätsklinikum Aachen
Affiliation as printed
Institute of Neuropathology, University Hospital RWTH Aachen, 52074 Aachen, Germany
-
Affiliation as printed
Department of Oral Medicine, Jining Medical University, Jining 272000, China
-
RWTH Aachen University · Universitätsklinikum Aachen
Affiliation as printed
Institute of Neuropathology, University Hospital RWTH Aachen, 52074 Aachen, Germany
Cited by 0 stored of 0
No patents citing this paper on Lens.org (checked 2026-10-06).
References 63
-
W2095807272details pending0citations
-
W4295896242details pending0citations
-
W1492555660details pending0citations
-
W2109025609details pending0citations
-
W2153429669details pending0citations
-
W2981679558details pending0citations
-
W2017821362details pending0citations
-
W1970519343details pending0citations
-
W1998699125details pending0citations
-
W2018637167details pending0citations
-
W2095634651details pending0citations
-
W2129447992details pending0citations