Imaging Performance Evaluation of a Human 7T BrainPET insert

Nuklearmedizin - NuclearMedicine, vol. 65, pp. 121

Abstract

Ziel/Aim: Acquiring hybrid MR/PET images simultaneously enables access to multiple biological parameters, including the function and structure of the human brain. We evaluated the imaging performance and MR compatibility of an in-house developed ultra-high field (UHF) MRI-compatible PET insert offering highest and homogeneous spatial resolution for in vivo neuroscientific studies, combining the advantages of UHF MRI with the molecular information obtained using PET. Methodik/Methods: The BrainPET-7T insert comprises 120 scintillation detectors arranged in five rings, allowing for a PET axial field of view (FOV) of 24.8 cm and an inner free diameter of 36.8 cm for inserting a custom-made transceiver array for dedicated head MR imaging which covers the entire PET FOV, and which has a patient opening of 27 cm. To achieve homogeneous spatial resolution across the entire PET FOV, each scintillation detector consists of three staggered layers of LSO, with a total of 1634 scintillation pixels and a pixel pitch of 2 mm. The performace evaluations were done according to the NEMA standards for human PET and the Standard IEC 62464 for determining essential image quality parameters of MRI. The mutual interference of both modalities was also evaluated. Ergebnisse/Results: The measured energy and timing resolutions (FWHM) of the 7T BrainPET insert are 14% and 620 ps, respectively. The PET transversal spatial resolution is≈1.6 mm and is not affected by MR. The peak NECR was measured to be 276 kcps at 16.3 kBq/ml and the system sensitivity without shielded coil array was 10.16% (energy window: 440-594 keV). The MR image SNR/image uniformity was 44.03/0.90 and 48.35/0.89 with and without PET, respectively. The RF noise acquisitions show no differences when comparing spurious noise scans with and without running PET. Schlussfolgerungen/Conclusion: The new 7T BrainPET insert system provides simultaneous high-quality PET and MR images with no relevant interference or incompatibility between the two modalities. Publication History Article published online: 02 April 2026 © 2026. Thieme. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany

Authors 32

  1. Forschungszentrum Jülich

    Affiliation as printed

    Institute of Neuroscience and Medicine (INM-4), Forschungszentrum Jülich GmbH, Jülich, Deutschland

  2. Forschungszentrum Jülich

    Affiliation as printed

    Institute of Neuroscience and Medicine (INM-4), Forschungszentrum Jülich GmbH, Jülich, Deutschland

  3. Forschungszentrum Jülich

    Affiliation as printed

    Institute of Neuroscience and Medicine (INM-4), Forschungszentrum Jülich GmbH, Jülich, Deutschland

  4. Forschungszentrum Jülich

    Affiliation as printed

    Institute of Neuroscience and Medicine (INM-4), Forschungszentrum Jülich GmbH, Jülich, Deutschland

  5. Forschungszentrum Jülich

    Affiliation as printed

    Institute of Neuroscience and Medicine (INM-4), Forschungszentrum Jülich GmbH, Jülich, Deutschland

  6. Forschungszentrum Jülich

    Affiliation as printed

    Institute of Neuroscience and Medicine (INM-4), Forschungszentrum Jülich GmbH, Jülich, Deutschland

  7. Forschungszentrum Jülich

    Affiliation as printed

    Institute of Neuroscience and Medicine (INM-4), Forschungszentrum Jülich GmbH, Jülich, Deutschland

  8. Affiliation as printed

    Affinity Imaging GmbH, Jülich, Deutschland

  9. Forschungszentrum Jülich

    Affiliation as printed

    Institute of Neuroscience and Medicine (INM-4), Forschungszentrum Jülich GmbH, Jülich, Deutschland

  10. Forschungszentrum Jülich

    Affiliation as printed

    Institute of Neuroscience and Medicine (INM-4), Forschungszentrum Jülich GmbH, Jülich, Deutschland

  11. Forschungszentrum Jülich

    Affiliation as printed

    Institute of Neuroscience and Medicine (INM-4), Forschungszentrum Jülich GmbH, Jülich, Deutschland

  12. Forschungszentrum Jülich

    Affiliation as printed

    Integrated Computing Architectures – Peter Grünberg Institute 4, Forschungszentrum Jülich, Jülich, Deutschland

  13. Forschungszentrum Jülich

    Affiliation as printed

    Integrated Computing Architectures – Peter Grünberg Institute 4, Forschungszentrum Jülich, Jülich, Deutschland

  14. Forschungszentrum Jülich

    Affiliation as printed

    Integrated Computing Architectures – Peter Grünberg Institute 4, Forschungszentrum Jülich, Jülich, Deutschland

  15. Forschungszentrum Jülich

    Affiliation as printed

    Institute of Technology and Engineering, Forschungszentrum Jülich, Jülich, Deutschland

  16. Forschungszentrum Jülich

    Affiliation as printed

    Institute of Technology and Engineering, Forschungszentrum Jülich, Jülich, Deutschland

  17. Forschungszentrum Jülich

    Affiliation as printed

    Institute of Technology and Engineering, Forschungszentrum Jülich, Jülich, Deutschland

  18. Forschungszentrum Jülich

    Affiliation as printed

    Institute of Technology and Engineering, Forschungszentrum Jülich, Jülich, Deutschland

  19. Forschungszentrum Jülich

    Affiliation as printed

    Institute of Technology and Engineering, Forschungszentrum Jülich, Jülich, Deutschland

  20. RWTH Aachen University

    Affiliation as printed

    Hyperion Hybrid Imaging Systems GmbH, Aachen, Deutschland

    Institute of Imaging & Computer Vision, RWTH Aachen, Aachen, Deutschland

  21. RWTH Aachen University

    Affiliation as printed

    Hyperion Hybrid Imaging Systems GmbH, Aachen, Deutschland

    Institute of Imaging & Computer Vision, RWTH Aachen, Aachen, Deutschland

  22. RWTH Aachen University

    Affiliation as printed

    Institute of Imaging & Computer Vision, RWTH Aachen, Aachen, Deutschland

  23. Affiliation as printed

    Hyperion Hybrid Imaging Systems GmbH, Aachen, Deutschland

  24. RWTH Aachen University

    Affiliation as printed

    Institute of Imaging & Computer Vision, RWTH Aachen, Aachen, Deutschland

  25. Affiliation as printed

    Hyperion Hybrid Imaging Systems GmbH, Aachen, Deutschland

  26. Forschungszentrum Jülich

    Affiliation as printed

    Institute of Neuroscience and Medicine 5, Forschungszentrum Jülich, Jülich, Deutschland

  27. RWTH Aachen University

    Affiliation as printed

    Institute of Experimental Molecular Imaging, RWTH Aachen, now with Bruker Biospin GmbH & Co KG, Aachen, Deutschland

  28. Affiliation as printed

    Inviscan Imaging Systems SA, Strasbourg, Frankreich

  29. Monash University

    Affiliation as printed

    Monash Biomedical Imaging, Monash University, Clayton, Monash, Australien

  30. Monash University

    Affiliation as printed

    Monash Biomedical Imaging, Monash University, Clayton, Monash, Australien

  31. RWTH Aachen University

    Affiliation as printed

    Hyperion Hybrid Imaging Systems GmbH, Aachen, Deutschland

    Institute of Imaging & Computer Vision, RWTH Aachen, Aachen, Deutschland

  32. Forschungszentrum Jülich · Jülich Aachen Research Alliance · RWTH Aachen University

    Affiliation as printed

    Department of Neurology, RWTH Aachen University, Aachen, Deutschland

    Institute of Neuroscience and Medicine (INM-4), Forschungszentrum Jülich GmbH, Jülich, Deutschland

    Institute of Neuroscience and Medicine – 11, JARA – BRAIN – Translational Medicine, Forschungszentrum Juelich, Jülich, Deutschland

Cited by 0 stored of 0

No patents citing this paper on Lens.org (checked 2026-10-06).

References 0