Efficient Interleaved Multi-Band Outer Volume Suppression for Highly Accelerated Simultaneous Multi-Slice Imaging of the Heart
Bioengineering, vol. 13, pp. 286
Abstract
In this work, we aimed to develop and evaluate multi-band outer volume suppression pulses for increased acceleration rates in simultaneous multi-slice accelerated cardiac MRI. MB-OVS pulses were constructed from a multi-band combination of two slab-selective saturation pulses and tested for various pulse shapes using Bloch simulation and phantom experiment. The MB-OVS pulses were interleaved between imaging pulses to ensure homogeneous suppression throughout the cardiac cycle/imaging window in vivo. Simultaneous multi-slice (SMS) CINE and first-pass myocardial perfusion scans with and without the proposed MB-OVS pulses were compared in terms of residual artifacts at high acceleration rates. Among the tested pulses, both Bloch simulation and phantom experiments showed that amplitude-optimized sinc pulses provided the best trade-off in suppression efficiency, the required B1+, SAR, and slab profile. CINE imaging with 5-fold SMS-OVS acceleration significantly outperformed imaging without MB-OVS, maintaining leakage-free image quality, even when adding 2-fold in-plane acceleration. SMS-OVS also enabled perfusion imaging in 9 slices with 1.7 × 1.7 mm2 resolution, achieving a 16-fold spatial-only acceleration while ensuring accurate contrast dynamics without leakage artifacts. Interleaved MB-OVS modules enabled thorough leakage artifact suppression in cardiac SMS-accelerated CINE and perfusion imaging, particularly at high acceleration rates. The proposed approach may be promising for unlocking further acceleration potential of SMS in cardiac imaging.
Authors 9
-
Leiden University Medical Center · Delft University of Technology
Affiliation as printed
Department of Imaging Physics, Delft University of Technology, 2628 CJ Delft, The Netherlands
Department of Radiology, Leiden University Medical Center, 2333 ZG Leiden, The Netherlands
-
Affiliation as printed
Philips North America, Rochester, MN 55902, USA
-
Affiliation as printed
Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, MN 55455, USA
Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN 55455, USA
-
Affiliation as printed
Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, MN 55455, USA
-
Delft University of Technology
Affiliation as printed
Department of Imaging Physics, Delft University of Technology, 2628 CJ Delft, The Netherlands
-
Delft University of Technology
Affiliation as printed
Department of Imaging Physics, Delft University of Technology, 2628 CJ Delft, The Netherlands
-
Leiden University Medical Center
Affiliation as printed
Department of Radiology, Leiden University Medical Center, 2333 ZG Leiden, The Netherlands
-
Affiliation as printed
Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, MN 55455, USA
Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN 55455, USA
-
Sebastian Weingärtner corresponding
Delft University of Technology
Affiliation as printed
Department of Imaging Physics, Delft University of Technology, 2628 CJ Delft, The Netherlands
Cited by 0 stored of 0
No patents citing this paper on Lens.org (checked 2026-10-11).