A

Training-Free Stimulus Encoding for Retinal Implants via Sparse Projected Gradient Descent

Proceedings - International Conference on Image Processing, pp. 1–6

Abstract

Retinal implants aim to restore functional vision despite photoreceptor degeneration, yet are fundamentally constrained by low resolution electrode arrays and patient-specific perceptual distortions. Most deployed encoders rely on task-agnostic downsampling and linear brightness-to-amplitude mappings, which are suboptimal under realistic perceptual models. While global inverse problems have been formulated as neural networks, such approaches can be fast at inference, and can achieve high reconstruction fidelity, but require training and have limited generalizability to arbitrary inputs. We cast stimulus encoding as a constrained sparse least-squares problem under a linearized perceptual forward model. Our key observation is that the resulting perception matrix can be highly sparse, depending on patient and implant configuration. Building on this, we apply an efficient projected residual norm steepest descent solver that exploits sparsity and supports stimulus bounds via projection. In silico experiments across four simulated patients and implant resolutions from $15\times15$ to $100\times100$ electrodes demonstrate improved reconstruction fidelity, with up to $+0.265$ SSIM increase, $+12.4\,\mathrm{dB}$ PSNR, and $81.4\%$ MAE reduction on Fashion-MNIST compared to Lanczos downsampling.

Authors 6

  1. RWTH Aachen University

    Affiliation as printed

    RWTH Aachen University

  2. Yuli Wu Aachen

    RWTH Aachen University

    Affiliation as printed

    RWTH Aachen University

  3. RWTH Aachen University

    Affiliation as printed

    RWTH Aachen University

  4. RWTH Aachen University

    Affiliation as printed

    RWTH Aachen University

  5. Peter Walter Aachen

    RWTH Aachen University

    Affiliation as printed

    RWTH Aachen University

  6. RWTH Aachen University

    Affiliation as printed

    RWTH Aachen University

Cited by 0 stored of 0

No patents citing this paper on Lens.org (checked 2026-10-06).

References 0