Evaluation of an interleaved acquisition scheme for improved robustness of channel‐wise relative B 1 + mapping at 7 T
Magnetic Resonance in Medicine, vol. 95, pp. 1157–1168
Abstract
Abstract Purpose The purpose was to evaluate, whether an interleaved acquisition scheme for a fast relative mapping method at 7 T reduces the likelihood of errors from exceeding the linear flip angle (FA) regime compared to a conventional sequential acquisition. Methods Simulations of a channel‐wise relative mapping sequence were performed for sequential and interleaved acquisition schemes at different reference voltages (≙ different FAs). The simulations were performed for a phantom, the heart and the prostate and were based on 7 T ground‐truth (GT) data acquired with an actual FA imaging sequence (phantom) or obtained from electromagnetic field simulations (heart/prostate). Acquisition schemes were evaluated based on their signal linearity by calculating a normalized mean FA error between simulated signal intensities and GT data. Additionally, validation measurements of relative maps with the sequential and interleaved acquisition schemes were acquired for the phantom. Results Validation measurements showed a good agreement with the simulation results for both acquisition schemes and displayed stronger deviations to the GT data for the sequential scheme. The quantitative evaluation yielded higher FA errors for the sequential acquisition scheme for all three regions and all simulated reference voltages. At the same level of error, mean signals were higher for the interleaved acquisition scheme in all cases. Differences between interleaved and sequential acquisition schemes were most pronounced in the steady‐state. Conclusion An interleaved acquisition of channel‐wise relative maps extends the range of the linear FA regime, reducing the likelihood of errors and increasing the robustness of the approach.
Authors 10
-
Nico Egger corresponding
Friedrich-Alexander-Universität Erlangen-Nürnberg · Universitätsklinikum Erlangen
Affiliation as printed
Institute of Radiology University Hospital Erlangen, Friedrich‐Alexander‐Universität Erlangen‐Nürnberg (FAU) Erlangen Germany
-
Friedrich-Alexander-Universität Erlangen-Nürnberg · Universitätsklinikum Erlangen
Affiliation as printed
Institute of Radiology University Hospital Erlangen, Friedrich‐Alexander‐Universität Erlangen‐Nürnberg (FAU) Erlangen Germany
-
Friedrich-Alexander-Universität Erlangen-Nürnberg · Universitätsklinikum Erlangen
Affiliation as printed
Institute of Radiology University Hospital Erlangen, Friedrich‐Alexander‐Universität Erlangen‐Nürnberg (FAU) Erlangen Germany
-
Friedrich-Alexander-Universität Erlangen-Nürnberg · Universitätsklinikum Erlangen
Affiliation as printed
Institute of Radiology University Hospital Erlangen, Friedrich‐Alexander‐Universität Erlangen‐Nürnberg (FAU) Erlangen Germany
-
Saskia Wildenberg Aachen
FH Aachen · Friedrich-Alexander-Universität Erlangen-Nürnberg · Universitätsklinikum Erlangen
Affiliation as printed
Electrical Engineering and Information Technology University of Applied Sciences ‐ FH Aachen Aachen Germany
Institute of Radiology University Hospital Erlangen, Friedrich‐Alexander‐Universität Erlangen‐Nürnberg (FAU) Erlangen Germany
Institute of Radiology University Hospital Erlangen, Friedrich‐Alexander‐Universität Erlangen‐Nürnberg (FAU) Erlangen Germany
-
Affiliation as printed
Electrical Engineering and Information Technology University of Applied Sciences ‐ FH Aachen Aachen Germany
Electrical Engineering and Information Technology, University of Applied Sciences - FH Aachen, Aachen, Germany
-
Siemens Healthineers (Germany)
Affiliation as printed
Siemens Healthcare Erlangen Germany
Siemens Healthcare, Erlangen, Germany
-
University of Minnesota · German Cancer Research Center · Physikalisch-Technische Bundesanstalt
Affiliation as printed
Center for Magnetic Resonance Research University of Minnesota Minneapolis Minnesota USA
Division of Medical Physics in Radiology German Cancer Research Centre (DKFZ) Heidelberg Germany
Physikalisch‐Technische Bundesanstalt (PTB) Braunschweig and Berlin Germany
Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA
Division of Medical Physics in Radiology, German Cancer Research Centre (DKFZ), Heidelberg, Germany
Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany
-
Friedrich-Alexander-Universität Erlangen-Nürnberg · Universitätsklinikum Erlangen
Affiliation as printed
Institute of Radiology University Hospital Erlangen, Friedrich‐Alexander‐Universität Erlangen‐Nürnberg (FAU) Erlangen Germany
-
Friedrich-Alexander-Universität Erlangen-Nürnberg · German Cancer Research Center · Universitätsklinikum Erlangen
Affiliation as printed
Division of Medical Physics in Radiology German Cancer Research Centre (DKFZ) Heidelberg Germany
Institute of Radiology University Hospital Erlangen, Friedrich‐Alexander‐Universität Erlangen‐Nürnberg (FAU) Erlangen Germany
Institute of Radiology University Hospital Erlangen, Friedrich‐Alexander‐Universität Erlangen‐Nürnberg (FAU) Erlangen Germany
Cited by 1 stored of 1
1 result
No patents citing this paper on Lens.org (checked 2026-10-06).
References 23
-
W2763823623details pending0citations
-
W2012104505details pending0citations
-
W2045527031details pending0citations
-
W2102728572details pending0citations
-
W3195788012details pending0citations
-
W4400090053details pending0citations
-
W1874295338details pending0citations
-
W2161191203details pending0citations
-
W3111311804details pending0citations
-
W3112088424details pending0citations
-
W3175657191details pending0citations
-
W3176388721details pending0citations
-
W4308366730details pending0citations
-
W4387356835details pending0citations