Timing resolution of a TOF-DOI detector module prototype for positron emission tomography
Journal of Instrumentation, vol. 20, pp. P07034
Abstract
Abstract To increase the image quality and spatial resolution in positron emission tomography (PET), organ-dedicated and large axial field of view scanners require precise correction of the parallax errors at oblique angles via depth-of-interaction methods. In addition to their large solid angle coverage, time-of-flight (TOF) information, i.e., a high coincidence time resolution (CTR), can be exploited to increase the image signal-to-noise ratio and effectively boost system sensitivity. Due to the impact of the photon travel time spread (PTS) on the TOF resolution, a high DOI resolution is essential to correct the impact of the PTS on the CTR and achieve even higher timing resolution. In this work, we present a TOF- and DOI-capable detector block with a CTR of 187 ps (FWHM) to 213 ps (FWHM), read out with the NINO and TOFPET2 ASIC, and a DOI resolution of 3.4 mm to 4.7 mm (RMSE), which distinguishes at least two DOI layers in the detector. Additionally, we established benchmarks for the CTR with custom high-frequency readout electronics. With these, a CTR of 136 ps (FWHM) can be maintained for a single TOF-DOI unit channel in the detector block.
Authors 10
-
Affiliation as printed
Department of Physics of Molecular Imaging Systems, University Hospital Aachen, Forckenbeckstrasse 55, Aachen, Germany
-
TU Wien · European Organization for Nuclear Research
Affiliation as printed
European Organization for Nuclear Research (CERN), 1 esplanade des particules, 1211 Geneve 23, Switzerland
Technical University of Vienna, Karlsplatz 13, Vienna, Austria
-
Affiliation as printed
Department of Physics of Molecular Imaging Systems, University Hospital Aachen, Forckenbeckstrasse 55, Aachen, Germany
-
Affiliation as printed
Department of Physics of Molecular Imaging Systems, University Hospital Aachen, Forckenbeckstrasse 55, Aachen, Germany
-
Affiliation as printed
Department of Physics of Molecular Imaging Systems, University Hospital Aachen, Forckenbeckstrasse 55, Aachen, Germany
-
Katrin Herweg Aachen Department of Physics of Molecular Imaging Systems Institute for Imaging and Computer Vision
Universitätsklinikum Aachen · RWTH Aachen University
Affiliation as printed
Department of Physics of Molecular Imaging Systems, University Hospital Aachen, Forckenbeckstrasse 55, Aachen, Germany
Institute for Imaging and Computer Vision, RWTH Aachen University, Kopernikusstrasse 16, Aachen, Germany
-
University of Milano-Bicocca · European Organization for Nuclear Research
Affiliation as printed
European Organization for Nuclear Research (CERN), 1 esplanade des particules, 1211 Geneve 23, Switzerland
University of Milano Bicocca, Piazza della Scienza, 3, Milan, Italy
-
European Organization for Nuclear Research
Affiliation as printed
European Organization for Nuclear Research (CERN), 1 esplanade des particules, 1211 Geneve 23, Switzerland
-
Affiliation as printed
Hyperion Hybrid Imaging Systems GmbH, Pauwelsstrasse 19, Aachen, Germany
Institute for Imaging and Computer Vision, RWTH Aachen University, Kopernikusstrasse 16, Aachen, Germany
Physics Institute III B, RWTH Aachen University, Sommerfeldstrasse 14, Aachen, Germany
-
Austrian Academy of Sciences · Universitätsklinikum Aachen · Institute of High Energy Physics
Affiliation as printed
Department of Physics of Molecular Imaging Systems, University Hospital Aachen, Forckenbeckstrasse 55, Aachen, Germany
Institute of High Energy Physics, Austrian Academy of Sciences, Nikolsdorfer Gasse 18, Vienna, Austria
Cited by 3 stored of 3
3 results
No patents citing this paper on Lens.org (checked 2026-10-06).