Fast maximum likelihood positioning for a staggered layer scintillation PET detector

Physics in Medicine and Biology, vol. 70, pp. 175018

Abstract

Abstract Objective. In this study, we propose a fast implementation of a maximum likelihood positioning (MLP) algorithm to estimate the energy and identify the active scintillator pixel in staggered layer scintillation detectors for positron emission tomograph (PET). Approach. High processing speed of the MLP algorithm was achieved by developing an iteration-free implementation paired with additional computational optimizations. Further, the MLP was implemented for a staggered layer design with pixelated scintillators which enables the determination of the gamma’s depth of interaction. The pixelation of the scintillator facilitates an iteration-free formulation of the MLP algorithm. The efficacy of the algorithm optimization was tested on a scintillation detector block designed for an ultra-high field BrainPET 7 T, comprising three scintillator pixel layers. Calibration measurements, in combination with an automated calibration script, were used to obtain the expected counts of scintillation photons required in the MLP algorithm. Main results. Using single-instruction-multiple-data parallelization, multi-threading and optimized cache lines, a maximum processing speed of approximately 22.5 million singles per second was achieved on a platform with four Intel Xeon Platinum 8168 CPUs and 60 threads, encompassing all required processing steps. The automatic calibration failed for 1–15 individual scintillator pixels in approximately 10% of the 120 scintillation detector blocks, necessitating manual correction. After applying the energy correction to the positioned single events, an energy resolution of Δ E = 12 % ± 2 % FWHM was obtained for the entire scintillation block. Significance. The obtained energy resolution is very close to the energy resolutions measured for the individual scintillator pixels, proving that the MLP accurately identifies the scintillating pixel and that the energy correction method effectively compensates for the light collection variations of the SiPM array. The presented method is not limited to PET and can be used as fast positioning and energy determination method with scintillation detectors for PET, SPECT and gamma cameras.

Authors 7

  1. Christoph W. Lerche corresponding

    Forschungszentrum Jülich

    Affiliation as printed

    Institute for Neuroscience and Medicine (INM-4), Forschungszentrum Jülich GmbH, Jülich, Germany

  2. Forschungszentrum Jülich · RWTH Aachen University

    Affiliation as printed

    Department of Physics, RWTH Aachen University, Aachen, Germany

    Institute for Neuroscience and Medicine (INM-4), Forschungszentrum Jülich GmbH, Jülich, Germany

  3. Qi Liu corresponding

    Forschungszentrum Jülich

    Affiliation as printed

    Institute for Neuroscience and Medicine (INM-4), Forschungszentrum Jülich GmbH, Jülich, Germany

    Institute of Neuroscience and Medicine 4, Forschungszentrum Jülich GmbH, Wilhelm-Johnen-Straße, Jülich, 52428, GERMANY

  4. Elisabeth A. G. Pfaehler corresponding

    Forschungszentrum Jülich

    Affiliation as printed

    Institute for Neuroscience and Medicine (INM-4), Forschungszentrum Jülich GmbH, Jülich, Germany

  5. Lutz Tellmann corresponding

    Forschungszentrum Jülich

    Affiliation as printed

    Institute for Neuroscience and Medicine (INM-4), Forschungszentrum Jülich GmbH, Jülich, Germany

  6. Jürgen J Scheins corresponding

    Forschungszentrum Jülich

    Affiliation as printed

    Institute for Neuroscience and Medicine (INM-4), Forschungszentrum Jülich GmbH, Jülich, Germany

  7. Forschungszentrum Jülich · Jülich Aachen Research Alliance · RWTH Aachen University

    Affiliation as printed

    Department of Neurology, RWTH Aachen University, Aachen, Germany

    Institute for Neuroscience and Medicine (INM-4), Forschungszentrum Jülich GmbH, Jülich, Germany

    Institute of Neuroscience and Medicine 11 (INM-11), Forschungszentrum Jülich GmbH, Jülich, Germany

    JARA-BRAIN-Translational Medicine, Jülich, Germany

    JARA—BRAIN—Translational Medicine, Jülich, Germany

Cited by 3 stored of 3

3 results

No patents citing this paper on Lens.org (checked 2026-10-06).

References 34