Integrating machine-readable user interface requirements into open networked operating rooms
Frontiers in Digital Health, vol. 7, pp. 1520584
Abstract
) must be performed to enable safe and usable interoperable medical device systems (according to IEEE 11073 SDC). This has to be fulfilled by applying recognized standards such as ISO 14971 (RM) and IEC 62366-1 (UE). Addressing the complexity of use cases with multiple network participants requires defining use context, hazardous situations, user profiles, user interfaces, system function contributions, limitations, configurations, and required conditions for safe use. We propose extending the categories mentioned in IEEE 11073-10700 with standardized user interface requirements provided by medical device manufacturers. A consumer of networked services can consider those UI Profiles containing design-, risk-, and process-related UI requirements during its design phase, usability engineering process, and risk management. This allows a systematic deficiency analysis prior to device usage, encompassing human-induced risks and thereby enhancing usability, patient safety, and finally operational efficiency. Using benchmarked, verified, and tested UI controls to create user interfaces that fulfill those requirements automatically might also be a solution for the future. This work presents an architectural overview incorporating ISO IEEE 11073-10700 standard requirements. Significantly, it extends these standards by introducing categories that enhance support for the usability engineering and risk management process, emphasizing the role of UI Profiles in achieving safe and usable operating room environments with more flexibility regarding interoperability and enabling a human-induced risk analysis prior to device usage. The number of surveyed manufacturers (8) and the need for real-world validation are limitations of this work, which should be validated by future work.
Authors 4
-
Affiliation as printed
Chair of Medical Engineering, Helmholtz-Institute for Biomedical Engineering, RWTH Aachen University, Aachen, Germany
-
Affiliation as printed
SurgiTAIX AG, Herzogenrath, Germany
-
Affiliation as printed
Chair of Medical Engineering, Helmholtz-Institute for Biomedical Engineering, RWTH Aachen University, Aachen, Germany
-
Affiliation as printed
Chair of Medical Engineering, Helmholtz-Institute for Biomedical Engineering, RWTH Aachen University, Aachen, Germany
Cited by 2 stored of 2
2 results
No patents citing this paper on Lens.org (checked 2026-10-06).
References 26
-
W2949023650details pending0citations
-
W4285263535details pending0citations
-
W2750233781details pending0citations
-
W1527595038details pending0citations
-
W1591162257details pending0citations
-
W1999829647details pending0citations
-
W2133345422details pending0citations
-
W2280416028details pending0citations
-
W2947810085details pending0citations
-
W3210123112details pending0citations
-
W4214558054details pending0citations
-
W4226457774details pending0citations
-
W4253918981details pending0citations
-
W4255066310details pending0citations
-
W4319431354details pending0citations
-
W4382563426details pending0citations
-
W4382644718details pending0citations