Contrast-Enhanced EIT Robustly Tracks Regional Lung Perfusion Compared to Non-Enhanced EIT and Pulmonary CT
IEEE Transactions on Medical Imaging, vol. 44, pp. 3683–3693
Abstract
Regional perfusion monitoring, often performed by pulmonary perfusion computed tomography, is vital in intensive care units. Electrical impedance tomography, repeatable and of non-invasive nature, could provide an attractive alternative. This study compares non-enhanced and contrast-enhanced electrical impedance tomography to computed tomography under induced central to peripheral lung perfusion impairments and cardiac output modulation in 11 animals. A new algorithmic framework using multi-compartment modeling and tracer kinetics was developed to improve perfusion estimation. A multi-resolution mixed models analysis shows electrical impedance tomography agrees poorly with computed tomography in static monitoring, with limits of agreement exceeding relative errors of 100%. For trend tracking,contrast-enhancement with 5.85% NaCl yielded concordance rates above 80%, and over 90% for peripheral impairments, emerging as a robust tracker of coarse to fine perfusion changes. Non-enhanced electrical impedance tomography peaked around 60% under central impairment and cardiac modulation, proving to be less reliable.
Authors 8
-
Diogo Silva Aachen Chair for Medical Information Technology Chair for Medical Information Technology
Universitätsklinikum Aachen · RWTH Aachen University
Affiliation as printed
Chair for Medical Information Technology, RWTH Aachen University Hospital, Aachen, Germany
Chair for Medical Information Technology, RWTH Aachen University, Germany
-
Düsseldorf University Hospital
Affiliation as printed
Department of Diagnostic and Interventional Radiology, University Hospital Düsseldorf, Düsseldorf, Germany
Department of Diagnostic and Interventional Radiology, University Hospital Düsseldorf, Germany
-
University of Bonn · University Hospital Bonn
Affiliation as printed
Department of Anaesthesiology and Intensive Care Medicine, University Hospital Bonn, Bonn, Germany
Department of Anaesthesiology and Intensive Care Medicine, University Hospital Bonn, Germany
-
University of Bonn · University Hospital Bonn
Affiliation as printed
Department of Anaesthesiology and Intensive Care Medicine, University Hospital Bonn, Bonn, Germany
Department of Anaesthesiology and Intensive Care Medicine, University Hospital Bonn, Germany
-
University of Bonn · University Hospital Bonn
Affiliation as printed
Department of Anaesthesiology and Intensive Care Medicine, University Hospital Bonn, Bonn, Germany
Department of Anaesthesiology and Intensive Care Medicine, University Hospital Bonn, Germany
-
Universitätsklinikum Aachen · RWTH Aachen University
Affiliation as printed
Department of Diagnostic and Interventional Radiology, University Hospital RWTH Aachen, Aachen, Germany
Department of Diagnostic and Interventional Radiology, University Hospital RWTH Aachen, Germany
-
University of Bonn · University Hospital Bonn · RWTH Aachen University
Affiliation as printed
Department of Anaesthesiology and Intensive Care Medicine, University Hospital Bonn, Bonn, Germany
Chair for Medical Information Technology, RWTH Aachen University, Germany
-
Steffen K. Leonhardt Aachen Chair for Medical Information Technology Chair for Medical Information Technology
Universitätsklinikum Aachen · RWTH Aachen University
Affiliation as printed
Chair for Medical Information Technology, RWTH Aachen University Hospital, Aachen, Germany
Chair for Medical Information Technology, RWTH Aachen University, Germany
Cited by 3 stored of 3
3 results
No patents citing this paper on Lens.org (checked 2026-10-06).