Compensating Sparse-view Inline Computed Tomography Artifacts with Neural Representation and Incremental Forward-Backward Network Architecture

e-Journal of Nondestructive Testing, vol. 30

Abstract

Sparse-view computed tomography (CT) is appealing for inline industrial quality control because it can significantly reduce scan acquisition times compared to full-view CT of 1-2 hours to a few minutes. This allows sparse view CT to be used in inline process manufacturing for 100% inspection of every component. However, the smaller number of projections in sparse-view CT scans leads to streak artifacts, which generally cause measurement deviations during the metrological inspection of components. Therefore, this paper discusses two deep-learning-based approaches for removing such artifacts. The two methods utilize a neural representation architecture to reproduce an estimate of the scanned object and then simulate a sparse-view forward projection to generate an artifact image. This approach was initially proposed for application in medical CT imaging, but it is modified for applications in inline industrial CT concerning speed. The two methods differ in how the neural representation is optimized during training. The first method is optimized based on an image-to-image basis, and the second method is on a projection basis. Our results show that both explored methods produce good correction results that lead to a promising minimization of surface deviation on the tested objects while meeting time constraints. This makes their application in industrial inline CT feasible.

Authors 5

  1. University of Stuttgart

    Affiliation as printed

    Department of Computational Imaging Systems , ITI , University of Stuttgart , Universitaetsstr. 39 , 70569 Stuttgart

  2. University of Stuttgart

    Affiliation as printed

    Department of Computational Imaging Systems , ITI , University of Stuttgart , Universitaetsstr. 39 , 70569 Stuttgart

  3. University of Stuttgart

    Affiliation as printed

    Department of Computational Imaging Systems , ITI , University of Stuttgart , Universitaetsstr. 39 , 70569 Stuttgart

  4. University of Stuttgart

    Affiliation as printed

    Department of Computational Imaging Systems , ITI , University of Stuttgart , Universitaetsstr. 39 , 70569 Stuttgart

  5. Ahmed Baraka Aachen

    RWTH Aachen University

    Affiliation as printed

    RWTH Aachen University , Campus-Boulevard 30 , 52074 Aachen , Germany,

Cited by 1 stored of 1

1 result

References 16

16 results