A Comparative Study of Supervised and Self-Supervised Denoising Techniques for Defect Segmentation in Industrial CT Imaging
e-Journal of Nondestructive Testing, vol. 30
Abstract
X-ray computed tomography (CT) is a powerful imaging tool for defect detection, segmentation and feature extraction in industrial applications as it enables non-destructive evaluation. The presence of artifacts and noise, however, imposes difficulties on the defect detection due to low contrast between defects and material. Different methods, the most recent ones based on deep learning, have been proposed to address both CT artifacts and noise. In this work, three state-of-the-art denoising techniques, namely BM3D, a supervised UNet and Noise2Inverse are compared with a novel approach based on a set of CNNs applied at different stages of the CT data acquisition pipeline. The comparison is done regarding the capabilities of the methods in terms of image quality enhancement as a preprocessing step in CT-based data analysis before performing defect segmentation.
Authors 11
-
Fraunhofer Institute for Integrated Circuits
Affiliation as printed
Fraunhofer Institute of Integrated Circuits IIS , Division Development Center X-ray Technology , Flugplatzstr. 75 , Fürth , 90768 , Germany
-
Affiliation as printed
Leiden Institute of Advanced Computer Science , Leiden Universiteit , Leiden , The Netherlands
-
Affiliation as printed
Leiden Institute of Advanced Computer Science , Leiden Universiteit , Leiden , The Netherlands
-
Affiliation as printed
Leiden Institute of Advanced Computer Science , Leiden Universiteit , Leiden , The Netherlands
-
Fraunhofer Institute for Integrated Circuits
Affiliation as printed
Fraunhofer Institute of Integrated Circuits IIS , Division Development Center X-ray Technology , Flugplatzstr. 75 , Fürth , 90768 , Germany
-
University of Passau · Fraunhofer Institute for Integrated Circuits
Affiliation as printed
Fraunhofer Institute of Integrated Circuits IIS , Division Development Center X-ray Technology , Flugplatzstr. 75 , Fürth , 90768 , Germany
University of Passau , Innstraße 43 , Passau , Germany
-
Fraunhofer Institute for Integrated Circuits
Affiliation as printed
Fraunhofer Institute of Integrated Circuits IIS , Division Development Center X-ray Technology , Flugplatzstr. 75 , Fürth , 90768 , Germany
-
Fraunhofer Institute for Integrated Circuits
Affiliation as printed
Fraunhofer Institute of Integrated Circuits IIS , Division Development Center X-ray Technology , Flugplatzstr. 75 , Fürth , 90768 , Germany
-
Dominik Wolfschläger Aachen
Affiliation as printed
WZL| RWTH Aachen University , Campus-Boulevard 30 , 52074 Aachen , Germany
-
Fraunhofer Institute for Production Technology IPT · RWTH Aachen University
Affiliation as printed
Fraunhofer IPT , Steinbergstr. 17 , 52074 Aachen , Germany
WZL| RWTH Aachen University , Campus-Boulevard 30 , 52074 Aachen , Germany
Cited by 0 stored of 0
No patents citing this paper on Lens.org (checked 2026-10-06).