Compensating the Meniscus Effect in Phase Contrast Microscopy Using an LCD for Adaptive Condenser Annulus Shifting
Microscopy Research and Technique, vol. 88, pp. 1534–1543
Abstract
The meniscus effect in cell culture vessels limits the observable areas with phase contrast microscopy. For meniscus effect compensation in microtiter plates (MTPs), we present a method using an LCD to replace the fixed condenser annulus, which enables adaptive annulus shifting based on image analysis. This approach led to an increase in phase contrast area by a factor of 8.3. Utilizing a standard phase contrast microscope, we substituted the static condenser annulus with a transparent LCD that displays an adaptive annulus, which can be repositioned to counteract meniscus-induced refraction across an entire MTP-24 well. We developed image analysis using Bertrand lens images to determine the misalignment between annulus center and phase ring, enabling the calculation of the required annulus shift. Experiments demonstrate the effectiveness of this image analysis technique. The detected shift was translated into new LCD settings through a linear regression model to ensure proper alignment for the following image. We proved that an algorithm based on background brightness yields a reliable metric for assessing phase contrast conditions within well-plates. The proposed approach substantially increased the phase contrast area in 24-well MTPs at 10× magnification from 5.0% with conventional microscopy to 41.9%, thereby restoring phase contrast conditions throughout the well, except near the edges.
Authors 3
-
Florian Nienhaus corresponding Aachen Fraunhofer Institute for Production Technology IPT Aachen Germany Fraunhofer Institute for Production Technology IPT
Fraunhofer Institute for Production Technology IPT
Affiliation as printed
Fraunhofer Institute for Production Technology IPT Aachen Germany
Fraunhofer Institute for Production Technology IPT, Aachen, Germany
-
Niels König Aachen Fraunhofer Institute for Production Technology IPT Aachen Germany Fraunhofer Institute for Production Technology IPT
Fraunhofer Institute for Production Technology IPT
Affiliation as printed
Fraunhofer Institute for Production Technology IPT Aachen Germany
Fraunhofer Institute for Production Technology IPT, Aachen, Germany
-
Robert Heinrich Schmitt Aachen Fraunhofer Institute for Production Technology IPT Aachen Germany Fraunhofer Institute for Production Technology IPT
RWTH Aachen University · Fraunhofer Institute for Production Technology IPT
Affiliation as printed
Fraunhofer Institute for Production Technology IPT Aachen Germany
WZL, RWTH Aachen University Aachen Germany
Fraunhofer Institute for Production Technology IPT, Aachen, Germany
WZL, RWTH Aachen University, Aachen, Germany
Cited by 1 stored of 1
1 result
No patents citing this paper on Lens.org (checked 2026-10-06).