Deep learning for 3D vascular segmentation in hierarchical phase contrast tomography: a case study on kidney
Scientific Reports, vol. 14, pp. 27258
Abstract
Automated blood vessel segmentation is critical for biomedical image analysis, as vessel morphology changes are associated with numerous pathologies. Still, precise segmentation is difficult due to the complexity of vascular structures, anatomical variations across patients, the scarcity of annotated public datasets, and the quality of images. Our goal is to provide a foundation on the topic and identify a robust baseline model for application to vascular segmentation using a new imaging modality, Hierarchical Phase-Contrast Tomography (HiP-CT). We begin with an extensive review of current machine-learning approaches for vascular segmentation across various organs. Our work introduces a meticulously curated training dataset, verified by double annotators, consisting of vascular data from three kidneys imaged using HiP-CT as part of the Human Organ Atlas Project. HiP-CT pioneered at the European Synchrotron Radiation Facility in 2020, revolutionizes 3D organ imaging by offering a resolution of around 20 μm/voxel and enabling highly detailed localised zooms up to 1-2 μm/voxel without physical sectioning. We leverage the nnU-Net framework to evaluate model performance on this high-resolution dataset, using both known and novel samples, and implementing metrics tailored for vascular structures. Our comprehensive review and empirical analysis on HiP-CT data sets a new standard for evaluating machine learning models in high-resolution organ imaging. Our three experiments yielded Dice similarity coefficient (DSC) scores of 0.9523, 0.9410, and 0.8585, respectively. Nevertheless, DSC primarily assesses voxel-to-voxel concordance, overlooking several crucial characteristics of the vessels and should not be the sole metric for deciding the performance of vascular segmentation. Our results show that while segmentations yielded reasonably high scores-such as centerline DSC ranging from 0.82 to 0.88, certain errors persisted. Specifically, large vessels that collapsed due to the lack of hydrostatic pressure (HiP-CT is an ex vivo technique) were segmented poorly. Moreover, decreased connectivity in finer vessels and higher segmentation errors at vessel boundaries were observed. Such errors, particularly in significant vessels, obstruct the understanding of the structures by interrupting vascular tree connectivity. Our study establishes the benchmark across various evaluation metrics, for vascular segmentation of HiP-CT imaging data, an imaging technology that has the potential to substantively shift our understanding of human vascular networks.
Authors 13
-
Ekin Yağış corresponding
Affiliation as printed
Department of Mechanical Engineering, University College London, London, UK. e.yagis@ucl.ac.uk
Department of Mechanical Engineering, University College London, London, UK
-
Affiliation as printed
Centre for Medical Image Computing, University College London, London, UK
Department of Mechanical Engineering, University College London, London, UK
-
Indiana University Bloomington · Indiana University
Affiliation as printed
Department of Intelligent Systems Engineering, Luddy School of Informatics, Computing, and Engineering, Indiana University, Bloomington, USA
-
Affiliation as printed
Department of Mechanical Engineering, University College London, London, UK
-
University College London · Imperial College London
Affiliation as printed
Department of Mechanical Engineering, University College London, London, UK
National Heart and Lung Institute, Faculty of Medicine, Imperial College London, London, UK
-
European Synchrotron Radiation Facility · University College London
Affiliation as printed
Department of Mechanical Engineering, University College London, London, UK
European Synchrotron Radiation Facility, Grenoble, France
-
Affiliation as printed
Laboratoire d'Anatomie Des Alpes Françaises, Grenoble, France
-
Medizinische Hochschule Hannover
Affiliation as printed
Institute of Pathology, Hannover Medical School, Carl-Neuberg-Straße 1, 30625, Hannover, Germany
-
University Medical Center of the Johannes Gutenberg University Mainz
Affiliation as printed
Institute of Functional and Clinical Anatomy, University Medical Center of the Johannes Gutenberg-University Mainz, Mainz, Germany
-
Affiliation as printed
Institute of Pathology, RWTH Aachen University, Pauwelsstrasse 30, 52074, Aachen, Germany
-
European Synchrotron Radiation Facility
Affiliation as printed
European Synchrotron Radiation Facility, Grenoble, France
-
Affiliation as printed
Department of Mechanical Engineering, University College London, London, UK
-
Affiliation as printed
Department of Mechanical Engineering, University College London, London, UK
Cited by 26 stored of 25
Cited by patents worldwide 1 (Lens.org)
-
Kidney puncture AI auxiliary data processing method and system based on artificial intelligenceCN120339302A 2025-07-18 Active