Prediction of Fan Array Performance with Polynomial and Support Vector Regression Models
International Journal of Turbomachinery Propulsion and Power, vol. 9, pp. 32
Abstract
The increasing utilisation of demand-controlled ventilation strategies leads to the frequent operation of fans under part-load conditions. To accurately predict the energy demand of a ventilation system with a fan array in the early design stages, models that calculate reliable results across the whole operating range are required. We present the comparison of a polynomial and a machine learning approach through support vector regression (SVR) to predict the fan performance over a wide range of typical operating points. For fitting and validation, we use experimental data. We investigate the extrapolation performance of both approaches. The SVR model achieves a slightly better representation of the experimental data with a lower error, especially when only sparse data are available. Both approaches yield similar results when the evaluation is conducted within the experimentally captured domain but deviates outside the domain. At operating points that are far from the experimentally captured domain, the polynomial models yield fan efficiencies that are physically plausible, while the SVR models drastically overpredict the fan efficiency. To rate the influence of such deviations towards modelling the actual energy demand, both approaches are applied to an operation simulation of a simplified office building. Both approaches yield similar results despite differing extrapolation capabilities.
Authors 4
-
Philipp Ostmann corresponding Aachen Institute for Energy Efficient Buildings and Indoor Climate E.ON Energy Research Center
Affiliation as printed
Institute for Energy Efficient Buildings and Indoor Climate, E.ON Energy Research Center, RWTH Aachen University, 52062 Aachen, Germany
-
Martin Rätz Aachen Institute for Energy Efficient Buildings and Indoor Climate E.ON Energy Research Center
Affiliation as printed
Institute for Energy Efficient Buildings and Indoor Climate, E.ON Energy Research Center, RWTH Aachen University, 52062 Aachen, Germany
-
Martin Kremer Aachen Institute for Energy Efficient Buildings and Indoor Climate E.ON Energy Research Center
Affiliation as printed
Institute for Energy Efficient Buildings and Indoor Climate, E.ON Energy Research Center, RWTH Aachen University, 52062 Aachen, Germany
-
Dirk Müller Aachen Institute for Energy Efficient Buildings and Indoor Climate E.ON Energy Research Center
Affiliation as printed
Institute for Energy Efficient Buildings and Indoor Climate, E.ON Energy Research Center, RWTH Aachen University, 52062 Aachen, Germany
Cited by 1 stored of 1
1 result
No patents citing this paper on Lens.org (checked 2026-10-06).
References 17
-
W6629804197details pending0citations
-
W6698097963details pending0citations
-
W6849179547details pending0citations
-
W6927169762details pending0citations
-
W6944069924details pending0citations
17 results