The impact of micro-vibrations on the METIS instrument
Abstract
The Mid-infrared ELT Imager and Spectrograph (METIS) is one of the first-light scientific instruments for the ELT with over 75 optical components. The science cases of METIS impose tight stability requirements on the optical performance. To assess whether the optical performance is harmed by micro-vibrations, the effect of numerous vibration sources on the optical stability are analyzed. We present the analysis approach and results for METIS. This includes finite element analysis to obtain transfer functions, compute rigid body motion response of optical elements and assess the optical impact by ray-tracing.
Authors 14
-
Netherlands Institute for Radio Astronomy
Affiliation as printed
ASTRON (Netherlands)
-
Netherlands Institute for Radio Astronomy
Affiliation as printed
ASTRON (Netherlands)
-
Netherlands Institute for Radio Astronomy
Affiliation as printed
ASTRON (Netherlands)
-
Affiliation as printed
European Southern Observatory (Germany)
-
Affiliation as printed
European Southern Observatory (Germany)
-
Affiliation as printed
European Southern Observatory (Germany)
-
Affiliation as printed
European Southern Observatory (Germany)
-
Max Planck Institute for Astronomy
Affiliation as printed
Max-Planck-Institut für Astronomie (Germany)
-
Max Planck Institute for Astronomy
Affiliation as printed
Max-Planck-Institut für Astronomie (Germany)
-
Affiliation as printed
Univ. de Lisboa (Portugal)
-
Science and Technology Facilities Council · UK Astronomy Technology Centre
Affiliation as printed
UK Astronomy Technology Ctr., Science and Technology Facilities Council (United Kingdom)
-
Affiliation as printed
Univ. zu Köln (Germany)
-
Leiden University · Leiden Observatory
Affiliation as printed
Leiden Observatory, Leiden Univ. (Netherlands)
-
Leiden University · Leiden Observatory
Affiliation as printed
Leiden Observatory, Leiden Univ. (Netherlands)
Cited by 0 stored of 0
No patents citing this paper on Lens.org (checked 2026-10-11).