Clinical Validation of Computer-Aided Diagnosis Software for Preventing Retained Surgical Sponges
Journal of the American College of Surgeons, vol. 238, pp. 856–860
Abstract
BACKGROUND: We previously reported the successful development of a computer-aided diagnosis (CAD) system for preventing retained surgical sponges with deep learning using training data, including composite and simulated radiographs. In this study, we evaluated the efficacy of the CAD system in a clinical setting. STUDY DESIGN: A total of 1,053 postoperative radiographs obtained from patients 20 years of age or older who underwent surgery were evaluated. We implemented a foreign object detection application software on the portable radiographic device used in the operating room to detect retained surgical sponges. The results of the CAD system diagnosis were prospectively collected. RESULTS: Among the 1,053 images, the CAD system detected possible retained surgical items in 150 images. Specificity was 85.8%, which is similar to the data obtained during the development of the software. CONCLUSIONS: The validation of a CAD system using deep learning in a clinical setting showed similar efficacy as during the development of the system. These results suggest that the CAD system can contribute to the establishment of a more effective protocol than the current standard practice for preventing the retention of surgical items.
Authors 9
-
Affiliation as printed
From the Department of Surgery, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki City, Japan (Kurisaki, Soyama, Yamaguchi, Matsuguma, Eguchi)
-
Affiliation as printed
From the Department of Surgery, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki City, Japan (Kurisaki, Soyama, Yamaguchi, Matsuguma, Eguchi)
-
Affiliation as printed
Imaging Technology Center, Research and Development Management Headquarters, FUJIFILM Corporation, Tokyo, Japan (Hamauzu, Yamada)
-
Affiliation as printed
Imaging Technology Center, Research and Development Management Headquarters, FUJIFILM Corporation, Tokyo, Japan (Hamauzu, Yamada)
-
Affiliation as printed
From the Department of Surgery, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki City, Japan (Kurisaki, Soyama, Yamaguchi, Matsuguma, Eguchi)
-
Leiden University Medical Center · Erasmus MC · Delft University of Technology
Affiliation as printed
Educational Program Technical Medicine, Leiden University Medical Center, Delft University of Technology and Erasmus MC Rotterdam, Rotterdam, The Netherlands (Kerkhof)
-
Leiden University Medical Center · Erasmus MC · Fujifilm (Japan) · Nagasaki University Hospital · Nagasaki University · Delft University of Technology
Affiliation as printed
Department of Radiology, Nagasaki University Hospital, Nagasaki City, Japan (Toya)
Educational Program Technical Medicine, Leiden University Medical Center, Delft University of Technology and Erasmus MC Rotterdam, Rotterdam, The Netherlands (Kerkhof)
From the Department of Surgery, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki City, Japan (Kurisaki, Soyama, Yamaguchi, Matsuguma, Eguchi)
Imaging Technology Center, Research and Development Management Headquarters, FUJIFILM Corporation, Tokyo, Japan (Hamauzu, Yamada)
Department of Radiology, Nagasaki University Hospital
-
Affiliation as printed
Department of Radiology, Nagasaki University Hospital, Nagasaki City, Japan (Toya)
-
Affiliation as printed
From the Department of Surgery, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki City, Japan (Kurisaki, Soyama, Yamaguchi, Matsuguma, Eguchi)
Cited by 3 stored of 3
3 results
No patents citing this paper on Lens.org (checked 2026-10-11).
References 18
-
W6657012414details pending0citations
-
W6674365231details pending0citations
-
W6715156949details pending0citations
18 results