A

Model-based super-resolution reconstruction for pseudo-continuous Arterial Spin Labeling

NeuroImage, vol. 286, pp. 120506

Abstract

Arterial spin labeling (ASL) is a promising, non-invasive perfusion magnetic resonance imaging technique for quantifying cerebral blood flow (CBF). Unfortunately, ASL suffers from an inherently low signal-to-noise ratio (SNR) and spatial resolution, undermining its potential. Increasing spatial resolution without significantly sacrificing SNR or scan time represents a critical challenge towards routine clinical use. In this work, we propose a model-based super-resolution reconstruction (SRR) method with joint motion estimation that breaks the traditional SNR/resolution/scan-time trade-off. From a set of differently oriented 2D multi-slice pseudo-continuous ASL images with a low through-plane resolution, 3D-isotropic, high resolution, quantitative CBF maps are estimated using a Bayesian approach. Experiments on both synthetic whole brain phantom data, and on in vivo brain data, show that the proposed SRR Bayesian estimation framework outperforms state-of-the-art ASL quantification.

Authors 7

  1. Quinten Beirinckx corresponding

    University of Antwerp

    Affiliation as printed

    imec-Vision Lab, Department of Physics, University of Antwerp, Antwerp, Belgium; μNEURO Research Centre of Excellence, University of Antwerp, Antwerp, Belgium

    imec-Vision Lab, Department of Physics, University of Antwerp, Antwerp, Belgium

    μNEURO Research Centre of Excellence, University of Antwerp, Antwerp, Belgium

  2. University of Antwerp

    Affiliation as printed

    imec-Vision Lab, Department of Physics, University of Antwerp, Antwerp, Belgium; μNEURO Research Centre of Excellence, University of Antwerp, Antwerp, Belgium

    imec-Vision Lab, Department of Physics, University of Antwerp, Antwerp, Belgium

    μNEURO Research Centre of Excellence, University of Antwerp, Antwerp, Belgium

  3. Leiden University Medical Center

    Affiliation as printed

    C.J. Gorter MRI Center, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands

  4. Leiden University Medical Center

    Affiliation as printed

    C.J. Gorter MRI Center, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands

  5. University of Antwerp

    Affiliation as printed

    imec-Vision Lab, Department of Physics, University of Antwerp, Antwerp, Belgium; Lab for Equilibrium Investigations and Aerospace, Department of Physics, University of Antwerp, Antwerp, Belgium; μNEURO Research Centre of Excellence, University of Antwerp, Antwerp, Belgium

    Lab for Equilibrium Investigations and Aerospace, Department of Physics, University of Antwerp, Antwerp, Belgium

    imec-Vision Lab, Department of Physics, University of Antwerp, Antwerp, Belgium

    μNEURO Research Centre of Excellence, University of Antwerp, Antwerp, Belgium

  6. University of Antwerp

    Affiliation as printed

    imec-Vision Lab, Department of Physics, University of Antwerp, Antwerp, Belgium; μNEURO Research Centre of Excellence, University of Antwerp, Antwerp, Belgium

    imec-Vision Lab, Department of Physics, University of Antwerp, Antwerp, Belgium

    μNEURO Research Centre of Excellence, University of Antwerp, Antwerp, Belgium

  7. University of Antwerp

    Affiliation as printed

    imec-Vision Lab, Department of Physics, University of Antwerp, Antwerp, Belgium; μNEURO Research Centre of Excellence, University of Antwerp, Antwerp, Belgium. Electronic address: jan.sijbers@uantwerpen.be

    imec-Vision Lab, Department of Physics, University of Antwerp, Antwerp, Belgium

    μNEURO Research Centre of Excellence, University of Antwerp, Antwerp, Belgium

Cited by 2 stored of 2

2 results

No patents citing this paper on Lens.org (checked 2026-10-11).

References 54