Survey on fan-beam computed tomography for radiotherapy: Current implementation and future perspectives of motion management and surface guidance devices

Physics and Imaging in Radiation Oncology, vol. 29, pp. 100523

Abstract

Background and purpose: This work reports on the results of a survey performed on the use of computed tomography (CT) imaging for motion management, surface guidance devices, and their quality assurance (QA). Additionally, it details the collected user insights regarding professional needs in CT for radiotherapy. The purpose of the survey is to understand current practice, professional needs and future directions in the field of fan-beam CT in radiation therapy (RT). Materials and methods: An online institutional survey was conducted between 1-Sep-2022 and 10-Oct-2022 among medical physics experts at Belgian and Dutch radiotherapy institutions, to assess the current status, challenges, and future directions of motion management and surface image-guided radiotherapy. The survey consisted of a maximum of 143 questions, with the exact number depending on participants' responses. Results: The response rate was 66 % (31/47). Respiratory management was reported as standard practice in all but one institution; surface imaging during CT-simulation was reported in ten institutions. QA procedures are applied with varying frequencies and methodologies, primarily with commercial anatomy-like phantoms. Surface guidance users report employing commercial static and dynamic phantoms. Four main subjects are considered clinically important by the respondents: surface guidance, CT protocol optimisation, implementing gated imaging (4DCT, breath-hold), and a tattoo-less workflow. Conclusions: The survey highlights the scattered pattern of QA procedures for respiratory motion management, indicating the need for well-defined, unambiguous, and practicable guidelines. Surface guidance is considered one of the most important techniques that should be implemented in the clinical radiotherapy simulation workflow.

Authors 11

  1. Chrysi Papalazarou corresponding Aachen

    Leiden University Medical Center

    Affiliation as printed

    Leiden University Medical Center, Leiden, the Netherlands

  2. Universitair Ziekenhuis Leuven

    Affiliation as printed

    Department of Radiation Oncology, University Hospitals Leuven, Leuven, Belgium

  3. Radiotherapeutisch Instituut Friesland

    Affiliation as printed

    Radiotherapy Institute Friesland, Leeuwarden, the Netherlands

  4. AZ Sint-Lucas

    Affiliation as printed

    Department of Radiotherapy, AZ Sint Lucas, Ghent, Belgium

  5. Maastricht University Medical Centre · Maastro Clinic

    Affiliation as printed

    Department of Radiation Oncology (Maastro Clinic), GROW School for Oncology, Maastricht University Medical Centre+, Maastricht, the Netherlands

  6. Radiotherapiegroep

    Affiliation as printed

    Radiotherapiegroep, Arnhem/Deventer, the Netherlands

  7. Affiliation as printed

    Department of Radiotherapy, AZ Sint-Maarten, Mechelen, Belgium

  8. Universitair Ziekenhuis Leuven · KU Leuven

    Affiliation as printed

    Department of Radiology, University Hospital Gasthuisberg, Leuven, Belgium

    Medical Physics and Quality Assessment, Department of Imaging and Pathology, KULeuven, Leuven, Belgium

  9. Ghent University · KU Leuven

    Affiliation as printed

    Department of Oncology, Laboratory of Experimental Radiotherapy, KU Leuven, Leuven, Belgium

    IBiTech-MEDISIP, Department of Electronics and Information Systems, Ghent University, Ghent, Belgium

  10. Ghent University Hospital

    Affiliation as printed

    Department of Radiation-Oncology, Ghent University Hospital, Ghent, Belgium

  11. Ghent University Hospital

    Affiliation as printed

    Department of Radiation-Oncology, Ghent University Hospital, Ghent, Belgium

Cited by 2 stored of 2

2 results

No patents citing this paper on Lens.org (checked 2026-10-11).

References 26