A

A unified approach for fatigue detail categorization applied to rack structures

Structures, vol. 56, pp. 104948

Abstract

Rack structures made of thin-walled cold-formed mild steel profiles integrate automated storage-and-retrieval (S&R) systems operating on a 24/7 basis to satisfy the current demands of warehouse logistics. The cyclic storage of palletized goods combined with dynamic actions from S&R systems results in fatigue phenomena responsible for interruptions. However, cold-formed steel is missing from current European standards for fatigue design. Answering to the industry’s needs, the FASTCOLD project financed by the RFCS of the EU investigated the problem, generating important fatigue data. Additionally, several fatigue details are categorized via a unified approach based on a large data set regarding full- and small-scale fatigue tests.

Authors 12

  1. Carlos d'Andrade Souto corresponding

    Universidade do Porto

    Affiliation as printed

    Department of Mechanical Engineering, Faculty of Engineering of the University of Porto, Porto, Portugal

  2. Fincons Group (Italy) · Politecnico di Milano

    Affiliation as printed

    Department of Architecture, Built Environment and Construction Engineering, Politecnico di Milano, Milano, Italy

    Fincon Consulting Italia Srl, Milano, Italy

  3. University of Pisa

    Affiliation as printed

    Department of Civil and Industrial Engineering, University of Pisa, Pisa, Italy

  4. University of Pisa

    Affiliation as printed

    Department of Civil and Industrial Engineering, University of Pisa, Pisa, Italy

  5. RWTH Aachen University

    Affiliation as printed

    Institute of Steel Construction, RWTH Aachen University, Aachen, Germany

  6. RWTH Aachen University

    Affiliation as printed

    Institute of Steel Construction, RWTH Aachen University, Aachen, Germany

  7. Hasselt University

    Affiliation as printed

    Faculty of Engineering Technology, Hasselt University, Hasselt, Belgium

  8. Affiliation as printed

    Shelter SA, Larissa, Greece

  9. Affiliation as printed

    FEM Racking and Shelving, Hitchin, England

  10. Universidade do Porto

    Affiliation as printed

    Department of Mechanical Engineering, Faculty of Engineering of the University of Porto, Porto, Portugal

  11. Affiliation as printed

    Institute of Science and Innovation in Mechanical and Industrial Engineering, Porto, Portugal

  12. Universidade do Porto

    Affiliation as printed

    Department of Mechanical Engineering, Faculty of Engineering of the University of Porto, Porto, Portugal

    Institute of Science and Innovation in Mechanical and Industrial Engineering, Porto, Portugal

Cited by 6 stored of 6

6 results

No patents citing this paper on Lens.org (checked 2026-10-06).

References 19

19 results