EVALUATING HARDWARE BUI LDI NG CONTROL I N THE CLOUD
Abstract
Many energy inefficiencies in buildings can be attributed to errors in control logic. This may be because of faulty hardware or incorrect programming. Within the context of a framework for testing building control, this paper evaluates controller operation using only monitored data. For a real building in operation, the performance of its control is analyzed with KPIs, and the causes of control errors are investigated automatically in the cloud. Possible improvements are suggested and the control code is updated using components from the open-source automation library AixOCAT. The process results in a better understanding of system behavior for the user.
Authors 4
-
Marwa Maghnie corresponding Aachen E.ON Energy Research Center Institute for Energy Efficient Buildings and Indoor Climate
Affiliation as printed
RWTH Aachen University , E.ON Energy Research Center , Institute for Energy Efficient Buildings and Indoor Climate , Mathieustraße 10 , 52074 , Aachen , Germany
RWTH Aachen University, E.ON Energy Research Center, Institute for Energy Efficient Buildings and Indoor Climate, Mathieustraße 10, 52074, Aachen, Germany
-
Felix Stegemerten Aachen E.ON Energy Research Center Institute for Energy Efficient Buildings and Indoor Climate
Affiliation as printed
RWTH Aachen University , E.ON Energy Research Center , Institute for Energy Efficient Buildings and Indoor Climate , Mathieustraße 10 , 52074 , Aachen , Germany
RWTH Aachen University, E.ON Energy Research Center, Institute for Energy Efficient Buildings and Indoor Climate, Mathieustraße 10, 52074, Aachen, Germany
-
Alexander Kümpel Aachen E.ON Energy Research Center Institute for Energy Efficient Buildings and Indoor Climate
Affiliation as printed
RWTH Aachen University , E.ON Energy Research Center , Institute for Energy Efficient Buildings and Indoor Climate , Mathieustraße 10 , 52074 , Aachen , Germany
RWTH Aachen University, E.ON Energy Research Center, Institute for Energy Efficient Buildings and Indoor Climate, Mathieustraße 10, 52074, Aachen, Germany
-
Dirk Müller Aachen E.ON Energy Research Center Institute for Energy Efficient Buildings and Indoor Climate
Affiliation as printed
RWTH Aachen University , E.ON Energy Research Center , Institute for Energy Efficient Buildings and Indoor Climate , Mathieustraße 10 , 52074 , Aachen , Germany
RWTH Aachen University, E.ON Energy Research Center, Institute for Energy Efficient Buildings and Indoor Climate, Mathieustraße 10, 52074, Aachen, Germany
Cited by 0 stored of 0
No patents citing this paper on Lens.org (checked 2026-10-06).
References 15
-
W2520654854details pending0citations
-
W7073978200details pending0citations
15 results