OPTIMIZATION OF A GRI D-INTERACTIVE BUILDING ENERGY SYSTEM CONSIDERING USER SATISFACTION
Abstract
Grid-interactive building energy systems (BES) enable the transition of buildings to flexible energy consumers. Nonetheless, occupant satisfaction, which is relevant for the spread of the technology, plays a subordinate role compared to costs in the research works on the grid-interactive BES operation. This work proposes a mixed-integer linear program (MILP) to integrate user aspects concerning thermal comfort and electric vehicle (EV) charging preferences in gridinteractive strategies. Applying the method to a singlefamily house shows that the simultaneous optimization of thermal comfort and costs is promising for the application scenario of the gridinteractive BES operation. Further, we demonstrate efficient integration strategies for EV charging scheduling.
Authors 4
-
Yizhuo Zhang corresponding Aachen E.ON Energy Research Center Institute for Energy Efficient Buildings and Indoor Climate Aachen Institute for Energy Efficient Buildings and
Affiliation as printed
RWTH Aachen University , E.ON Energy Research Center , Institute for Energy Efficient Buildings and Indoor Climate Aachen , Deutschland ,
Indoor Climate Aachen, Deutschland,
RWTH Aachen University, E.ON Energy Research Center, Institute for Energy Efficient Buildings and
-
Tori Wiederhöft Aachen E.ON Energy Research Center Institute for Energy Efficient Buildings and Indoor Climate Aachen Institute for Energy Efficient Buildings and
Affiliation as printed
RWTH Aachen University , E.ON Energy Research Center , Institute for Energy Efficient Buildings and Indoor Climate Aachen , Deutschland ,
Indoor Climate Aachen, Deutschland,
RWTH Aachen University, E.ON Energy Research Center, Institute for Energy Efficient Buildings and
-
Thomas Schreiber Aachen E.ON Energy Research Center Institute for Energy Efficient Buildings and Indoor Climate Aachen Institute for Energy Efficient Buildings and
Affiliation as printed
RWTH Aachen University , E.ON Energy Research Center , Institute for Energy Efficient Buildings and Indoor Climate Aachen , Deutschland ,
Indoor Climate Aachen, Deutschland,
RWTH Aachen University, E.ON Energy Research Center, Institute for Energy Efficient Buildings and
-
Dirk Müller Aachen E.ON Energy Research Center Institute for Energy Efficient Buildings and Indoor Climate Aachen Institute for Energy Efficient Buildings and
Affiliation as printed
RWTH Aachen University , E.ON Energy Research Center , Institute for Energy Efficient Buildings and Indoor Climate Aachen , Deutschland ,
Indoor Climate Aachen, Deutschland,
RWTH Aachen University, E.ON Energy Research Center, Institute for Energy Efficient Buildings and
Cited by 0 stored of 0
No patents citing this paper on Lens.org (checked 2026-10-06).
References 18
-
W6697396069details pending0citations
18 results