T2* quantification using multi-echo gradient echo sequences: a comparative study of different readout gradients
Scientific Reports, vol. 13, pp. 1138
Abstract
To quantify T2*, multiple echoes are typically acquired with a multi-echo gradient echo sequence using either monopolar or bipolar readout gradients. The use of bipolar readout gradients achieves a shorter echo spacing time, enabling the acquisition of a larger number of echoes in the same scan time. However, despite their relative time efficiency and the potential for more accurate quantification, a comparative investigation of these readout gradients has not yet been addressed. This work aims to compare the performance of monopolar and bipolar readout gradients for T2* quantification. The differences in readout gradients were theoretically investigated with a Cramér-Rao lower bound and validated with computer simulations with respect to the various imaging parameters (e.g., flip angle, TR, TE, TE range, and BW). The readout gradients were then compared at 3 T using phantom and in vivo experiments. The bipolar readout gradients provided higher precision than monopolar readout gradients in both computer simulations and experimental results. The difference between the two readout gradients increased for a lower SNR and smaller TE range, consistent with the prediction made using Cramér-Rao lower bound. The use of bipolar readout gradients is advantageous for regions or situations where a lower SNR is expected or a shorter acquisition time is required.
Authors 3
-
Seonyeong Shin Aachen
RWTH Aachen University · Forschungszentrum Jülich
Affiliation as printed
Institute of Neuroscience and Medicine 4, Forschungszentrum Jülich, INM-4, 52428, Jülich, Germany
RWTH Aachen University, Aachen, Germany
-
Affiliation as printed
Institute of Neuroscience and Medicine 4, Forschungszentrum Jülich, INM-4, 52428, Jülich, Germany
-
RWTH Aachen University · Forschungszentrum Jülich · Jülich Aachen Research Alliance
Affiliation as printed
Department of Neurology, RWTH Aachen University, Aachen, Germany. n.j.shah@fz-juelich.de
Institute of Neuroscience and Medicine 11, JARA, Forschungszentrum Jülich, INM-11, Jülich, Germany. n.j.shah@fz-juelich.de
Institute of Neuroscience and Medicine 4, Forschungszentrum Jülich, INM-4, 52428, Jülich, Germany. n.j.shah@fz-juelich.de
JARA-BRAIN-Translational Medicine, Aachen, Germany. n.j.shah@fz-juelich.de
RWTH Aachen University, Aachen, Germany. n.j.shah@fz-juelich.de
Institute of Neuroscience and Medicine 4, Forschungszentrum Jülich, INM-4, 52428, Jülich, Germany
RWTH Aachen University, Aachen, Germany
Cited by 7 stored of 7
7 results
Cited by patents worldwide 1 (Lens.org)
-
Magnetic resonance imaging method, device, equipment, readable storage medium and program productCN121596184A 2026-03-03 Pending
References 34
-
W2163641775details pending0citations
-
W2009423817details pending0citations
-
W2079564353details pending0citations
-
W2288459369details pending0citations
-
W2993277982details pending0citations
-
W2152679646details pending0citations
-
W2029723709details pending0citations
-
W1928162906details pending0citations
-
W1958916310details pending0citations
-
W1965118917details pending0citations
-
W1966234248details pending0citations
-
W1979137667details pending0citations
-
W1980178045details pending0citations
-
W2011126431details pending0citations
-
W2017475987details pending0citations
-
W2018384752details pending0citations