Effervescent Atomizer as Novel Cell Spray Technology to Decrease the Gas-to-Liquid Ratio
Pharmaceutics, vol. 14, pp. 2421
Abstract
Cell spraying has become a feasible application method for cell therapy and tissue engineering approaches. Different devices have been used with varying success. Often, twin-fluid atomizers are used, which require a high gas velocity for optimal aerosolization characteristics. To decrease the amount and velocity of required air, a custom-made atomizer was designed based on the effervescent principle. Different designs were evaluated regarding spray characteristics and their influence on human adipose-derived mesenchymal stromal cells. The arithmetic mean diameters of the droplets were 15.4−33.5 µm with decreasing diameters for increasing gas-to-liquid ratios. The survival rate was >90% of the control for the lowest gas-to-liquid ratio. For higher ratios, cell survival decreased to approximately 50%. Further experiments were performed with the design, which had shown the highest survival rates. After seven days, no significant differences in metabolic activity were observed. The apoptosis rates were not influenced by aerosolization, while high gas-to-liquid ratios caused increased necrosis levels. Tri-lineage differentiation potential into adipocytes, chondrocytes, and osteoblasts was not negatively influenced by aerosolization. Thus, the effervescent aerosolization principle was proven suitable for cell applications requiring reduced amounts of supplied air. This is the first time an effervescent atomizer was used for cell processing.
Authors 9
-
Anja Lena Thiebes corresponding Aachen Department of Biohybrid and Medical Textiles (BioTex) AME-Institute of Applied Medical Engineering
Maastricht University · RWTH Aachen University
Affiliation as printed
Aachen-Maastricht Institute for Biobased Materials, Faculty of Science and Engineering, Maastricht University, Brightlands Chemelot Campus, Urmonderbaan 22, 6167 RD Geleen, The Netherlands
Department of Biohybrid & Medical Textiles (BioTex), AME—Institute of Applied Medical Engineering, Helmholtz Institute Aachen, RWTH Aachen University, Forckenbeckstraße 55, 52074 Aachen, Germany
-
Sarah Klein Aachen Department of Biohybrid and Medical Textiles (BioTex) AME-Institute of Applied Medical Engineering
Maastricht University · RWTH Aachen University
Affiliation as printed
Aachen-Maastricht Institute for Biobased Materials, Faculty of Science and Engineering, Maastricht University, Brightlands Chemelot Campus, Urmonderbaan 22, 6167 RD Geleen, The Netherlands
Department of Biohybrid & Medical Textiles (BioTex), AME—Institute of Applied Medical Engineering, Helmholtz Institute Aachen, RWTH Aachen University, Forckenbeckstraße 55, 52074 Aachen, Germany
-
Jonas Zingsheim Aachen Department of Biohybrid and Medical Textiles (BioTex) AME-Institute of Applied Medical Engineering Laboratory Biomaterial
RWTH Aachen University · FH Aachen
Affiliation as printed
Department of Biohybrid & Medical Textiles (BioTex), AME—Institute of Applied Medical Engineering, Helmholtz Institute Aachen, RWTH Aachen University, Forckenbeckstraße 55, 52074 Aachen, Germany
Laboratory Biomaterial, University of Applied Sciences Aachen, Heinrich-Mußmann-Straße 1, 52428 Jülich, Germany
-
Affiliation as printed
Institute of Heat and Mass Transfer (WSA), RWTH Aachen University, Augustinerbach 6, 52056 Aachen, Germany
-
Affiliation as printed
Institute of Heat and Mass Transfer (WSA), RWTH Aachen University, Augustinerbach 6, 52056 Aachen, Germany
-
Affiliation as printed
Institute of Heat and Mass Transfer (WSA), RWTH Aachen University, Augustinerbach 6, 52056 Aachen, Germany
-
Affiliation as printed
Laboratory Biomaterial, University of Applied Sciences Aachen, Heinrich-Mußmann-Straße 1, 52428 Jülich, Germany
-
Stefan Jockenhoevel corresponding Aachen Department of Biohybrid and Medical Textiles (BioTex) AME-Institute of Applied Medical Engineering
Maastricht University · RWTH Aachen University
Affiliation as printed
Aachen-Maastricht Institute for Biobased Materials, Faculty of Science and Engineering, Maastricht University, Brightlands Chemelot Campus, Urmonderbaan 22, 6167 RD Geleen, The Netherlands
Department of Biohybrid & Medical Textiles (BioTex), AME—Institute of Applied Medical Engineering, Helmholtz Institute Aachen, RWTH Aachen University, Forckenbeckstraße 55, 52074 Aachen, Germany
-
Christian Gabriel Cornelissen Aachen Department of Biohybrid and Medical Textiles (BioTex) AME-Institute of Applied Medical Engineering Department of Pneumology and Internal Intensive Care Medicine Medical Clinic V
Universitätsklinikum Aachen · RWTH Aachen University
Affiliation as printed
Department of Biohybrid & Medical Textiles (BioTex), AME—Institute of Applied Medical Engineering, Helmholtz Institute Aachen, RWTH Aachen University, Forckenbeckstraße 55, 52074 Aachen, Germany
Department of Pneumology and Internal Intensive Care Medicine, Medical Clinic V, University Hospital RWTH Aachen, Pauwelsstraße 30, 52074 Aachen, Germany
Cited by 3 stored of 3
3 results
No patents citing this paper on Lens.org (checked 2026-10-06).
References 25
-
W6717691643details pending0citations