The effects of tether pretension within vertebral body tethering on the biomechanics of the spine: a Finite Element analysis
Latin American Journal of Solids and Structures, vol. 19
Abstract
This study investigates the biomechanics of the spine after insertion of vertebral body tethering (VBT) with different cord pretensions. For that purpose, a Finite Element model of the average thoracolumbar spine was stepwise calibrated and validated. The VBT instrumentation was inserted in the left side of the L1-L2 segment with different cord pretensions. As a second test, the L1-L2 segment was submitted to an external pure moment of 6 Nm in left and right lateral bending. The range of motion (ROM) for the spine with VBT was determined with respect to its initial post VBT position. Pretension forces of 100 N and 300 N resulted in a change of scoliotic angle of 2.7° and 5.3° to the left side of the spine, respectively. The ROM of the native spine was 4.5° in right lateral bending and reduced to 1.8° and 1.4° for the cases of the spine with a cord pretension of 100 N and 300 N, respectively. In left lateral bending, the absolute ROM of the native spine was 4.6°. For the cases of a cord pretension of 100 N and 300 N, the spine bent 1.9° and 0.8° to the left side from its initial post VBT position, respectively.
Authors 10
-
Universidade Federal de Santa Catarina
Affiliation as printed
Universidade Federal de Santa Catarina, Brasil; Universidade Federal de Santa Catarina, Brasil
Universidade Federal de Santa Catarina, Brasil; Universidade Federal de Santa Catarina, Brasil
-
Johannes Greven Aachen
RWTH Aachen University · Universitätsklinikum Aachen
Affiliation as printed
RWTH Aachen University Hospital, Germany
RWTH Aachen University Hospital, Germany
-
Philipp Kobbe Aachen
RWTH Aachen University · Universitätsklinikum Aachen
Affiliation as printed
RWTH Aachen University Hospital, Germany
RWTH Aachen University Hospital, Germany
-
Frank Hildebrand Aachen
RWTH Aachen University · Universitätsklinikum Aachen
Affiliation as printed
RWTH Aachen University Hospital, Germany
RWTH Aachen University Hospital, Germany
-
Marcus Stoffel Aachen
Affiliation as printed
RWTH Aachen University, Germany
RWTH Aachen University, Germany
-
Bernd A. Markert Aachen
Affiliation as printed
RWTH Aachen University, Germany
RWTH Aachen University, Germany
-
Universidade Federal de Santa Catarina
Affiliation as printed
Universidade Federal de Santa Catarina, Brasil
Universidade Federal de Santa Catarina, Brasil
-
Universidade Federal de Santa Catarina
Affiliation as printed
Universidade Federal de Santa Catarina, Brasil
Universidade Federal de Santa Catarina, Brasil
-
Universidade Federal de Santa Catarina
Affiliation as printed
Universidade Federal de Santa Catarina, Brasil; Universidade Federal de Santa Catarina, Brasil
Universidade Federal de Santa Catarina, Brasil; Universidade Federal de Santa Catarina, Brasil
-
Universidade Federal de Santa Catarina
Affiliation as printed
Universidade Federal de Santa Catarina, Brasil; Universidade Federal de Santa Catarina, Brasil
Universidade Federal de Santa Catarina, Brasil; Universidade Federal de Santa Catarina, Brasil
Cited by 8 stored of 8
8 results
No patents citing this paper on Lens.org (checked 2026-10-06).
References 58
-
W2312000677details pending0citations
-
W2270948904details pending0citations
-
W1968722331details pending0citations
-
W1979137267details pending0citations
-
W1991897750details pending0citations
-
W1996943815details pending0citations
-
W2000676270details pending0citations
-
W2001931001details pending0citations