DO AUTOMATED, U-NET-BASED CARTILAGE SEGMENTATIONS FROM MRI BENEFIT FROM MANUAL QUALITY CONTROL AND CORRECTION? DATA FROM THE IMI-APPROACH PROJECT

Osteoarthritis Imaging, vol. 2, pp. 100016

Abstract

Automated, U-Net-based cartilage segmentations have been reported to provide a high sensitivity to cartilage thickness loss. Still, there is no perfect agreement between U-Net and manual segmentations, in particular in OA knees, and outliers with incorrect segmentations may impair the U-Net performance. To evaluate the performance of automated, U-Net-based segmentations of MRIs with and without additional manual quality control and correction (QC&C) and the time effort required for QC&C. 2D U-Nets were trained separately for the medial (MFTC) and the lateral (LFTC) femorotibial compartment of the knee using manual segmentations from 3D MRI acquired by IMI-APPROACH (training/ validation set: n=100/25). The U-Nets were then applied to 26 knees with accelerated MFTC cartilage thickness loss over 2 years and 16 knees without any cartilage loss (age: 67.2±6.8y, 57% females). Subsequently, U-Net-based segmentations were checked and corrected by 5 experienced readers before additional expert quality control. The QC&C required approximately 60% of the time of fully manual segmentations and was reported to be more tedious than performing segmentations from scratch. The agreement (DSC=Dice Similarity Coefficient) of automated vs. manual segmentations before QC&C ranged from 0.83±0.12 to 0.89±0.05 for the 4 femorotibial cartilages and was between 0.89 ± 0.06 and 0.92 ± 0.03 after QC&C. The baseline cartilage thickness was greater for U-Net-based than for manual segmentations in both the MFTC (3.23±0.50mm, 95%CI: [3.07, 3.39] vs. 2.98±0.79mm, 95%CI: [2.73, 3.22]) and LFTC (3.78±0.61mm, 95%CI: [3.59, 3.97] vs. 3.61±0.74mm, 95%CI: [3.38, 3.84]). After QC&C, the observed cartilage thickness (MFTC: 3.00±0.78mm, 95%CI: [2.76, 3.25], LFTC: 3.66±0.7mm, 95%CI: [3.44, 3.88]) was closer to that obtained from manual segmentations. The 2-year cartilage thickness change in the MFTC of knees without cartilage loss was consistent between all 3 methods (manual: 0.01±0.07mm, 95%CI: [-0.03, 0.05], without QC&C: 0.04±0.11mm, 95%CI: [-0.02, 0.10], with QC&C: 0.05±0.12mm, 95%CI: [-0.01, 0.12]). In knees with cartilage loss, the MFTC change tended to be lower before QC&C (-0.22±0.29mm, 95%CI: [-0.34, -0.11]) and with QC&C (-0.22±0.17mm, 95%CI: [-0.28, -0.15]) than for manual segmentations (-0.32±0.17mm, 95%CI: [-0.39, -0.25]). The effect size (Cohen's D) for differences in change between knees with vs. without cartilage loss was greatest for manual segmentations (2.28), followed by U-Net segmentations with QC&C (1.78) and without QC&C (1.13). The sensitivity to change (SRM=standardized response mean) in the MFTC of knees with thickness loss was greatest for manual segmentations (-1.83) followed by the U-Net with QC&C (-1.30) and without QC&C (-0.78). The lower change observed with U-Net-based segmentations may partially be attributed to a regression to the mean effect caused by specifically selecting the knees with the greatest cartilage thickness loss. Still, manual QC&C improved the agreement of automated and manual segmentations and resulted in a greater sensitivity to differences in cartilage thickness loss and also to a greater sensitivity to change when compared to fully-automated U-Net segmentations. This improvement required, however, a substantial amount of time. EU/EFPIA Innovative Medicines Initiative Joint Undertaking (grant n° 115770). AW, SM, FE, WW: Chondrometrics GmbH; FWR: Boston Imaging Core Lab; CHL: Merck KGaA (during the conduct of the study) and grants from IMI-APPROACH IMI-APPROACH (NCT03883568) participants and investigators CORRESPONDENCE ADDRESS: [email protected]

Authors 15

  1. Paracelsus Medical University

    Affiliation as printed

    Chondrometrics GmbH, Freilassing, Germany & Paracelsus Med. University, Salzburg, Austria

  2. Paracelsus Medical University

    Affiliation as printed

    Chondrometrics GmbH, Freilassing, Germany & Paracelsus Med. University, Salzburg, Austria

  3. University Medical Center Utrecht

    Affiliation as printed

    University Medical Center Utrecht, Utrecht, Netherlands

  4. University Medical Center Utrecht

    Affiliation as printed

    University Medical Center Utrecht, Utrecht, Netherlands

  5. University Medical Center Utrecht

    Affiliation as printed

    University Medical Center Utrecht, Utrecht, Netherlands

  6. Servier (France)

    Affiliation as printed

    Servier, Suresnes, France

  7. University Medical Center Utrecht

    Affiliation as printed

    University Medical Center Utrecht, Utrecht, Netherlands

  8. Universidade da Coruña · Instituto de Investigación Biomédica de A Coruña

    Affiliation as printed

    INIBIC-Universidade de A Coruña (UDC), A Coruña, Spain

  9. Inserm · Sorbonne Université · Hôpital Saint-Antoine

    Affiliation as printed

    Sorbonne University, Inserm, APHP hôpital Saint-Antoine, Paris, France

  10. Leiden University Medical Center

    Affiliation as printed

    Leiden University Medical Center, Leiden, Netherlands

  11. Diakonhjemmet Hospital

    Affiliation as printed

    Diakonhjemmet Hospital, Oslo, Norway

  12. Affiliation as printed

    Consultant, Germany

  13. Boston University · Universitätsklinikum Erlangen

    Affiliation as printed

    University Hospital & University of Erlangen, Erlangen, Germany & Boston University School of Medicine, Boston, MA, USA

  14. Paracelsus Medical University

    Affiliation as printed

    Chondrometrics GmbH, Freilassing, Germany & Paracelsus Med. University, Salzburg, Austria

  15. Paracelsus Medical University

    Affiliation as printed

    Chondrometrics GmbH, Freilassing, Germany & Paracelsus Med. University, Salzburg, Austria

Cited by 1 stored of 1

1 result

No patents citing this paper on Lens.org (checked 2026-10-11).

References 0