A

Anatomical analysis of different helical plate designs for proximal humeral shaft fracture fixation

British journal of surgery, vol. 109

Abstract

Abstract Objective Helical plates are preferably used for proximal humeral shaft fracture fixation with metaphyseal extension into the humeral head and potentially avoid radial nerve irritation as compared to straight plates. The aims of this study were: (1) to investigate the safety of applying different long plate designs (straight, 45°-, 90°-helical and ALPS) in MIPO-technique to the humerus and (2) to assess and compare their distances to adjacent anatomical structures at risk. Methods MIPO was performed in 16 human cadaveric humeri using either a straight plate (group1), a 45°-helical (group2), a 90°-helical (group3) or an ALPS (group4). Using CT-angiography, distances between brachial arteries and plates were evaluated. Following, all specimens were dissected, and distances to the axillary, radial and musculocutaneous nerve were evaluated. Results None of the specimens demonstrated injuries of the anatomical structures at risk after MIPO with all investigated plate designs. Closest overall distance (mm(range)) between each plate and the radial nerve was 1(1–3) in group1, 7(2–11) in group2, 14(7–25) in group3 and 6(3–8) in group4. It was significantly longer in group3 and significantly shorter in group1 as compared to all other groups, p<0.001. Closest overall distance (mm(range)) between each plate and the musculocutaneous nerve was 16(8–28) in group1, 11(7–18) in group2, 3(2–4) in group3 and 6(3–8) in group4. It was significantly longer in group1 and significantly shorter in group3 as compared to all other groups, p<0.001. Closest overall distance (mm(range)) between each plate and the brachial artery was 21(18–23) in group1, 7(6–7) in group2, 4(3–5) in group3 and 7(6–7) in group4. It was significantly longer in group1 and significantly shorter in group3 as compared to all other groups, p<0.021. Conclusion MIPO with 45°- and 90°-helical plates as well as ALPS is safely feasible and showed a significant greater distance to the radial nerve compared to straight plates. However, distances remain low, and attention must be paid to the musculocutaneous nerve and the brachial artery when MIPO is used with ALPS, 45°- and 90°-helical implants. Moreover, the anterior part of the deltoid insertion will be detached when using 90°-helical and ALPS implants in MIPO-technique.

Authors 13

  1. Luzerner Kantonsspital · AO Foundation

    Affiliation as printed

    AO Research Institute Davos Biomechanical Development, , Davos, Switzerland

    Department of Orthopaedic and Trauma Surgery, Cantonal Hospital Lucerne , Lucerne, Switzerland

  2. AO Foundation

    Affiliation as printed

    AO Research Institute Davos Biomechanical Development, , Davos, Switzerland

  3. AO Foundation

    Affiliation as printed

    AO Research Institute Davos Biomechanical Development, , Davos, Switzerland

  4. AO Foundation

    Affiliation as printed

    AO Research Institute Davos Biomechanical Development, , Davos, Switzerland

  5. RWTH Aachen University · Universitätsklinikum Aachen

    Affiliation as printed

    Department of Orthopaedic and Traumatology, Aachen University Hospital , Aachen, Germany

  6. Luzerner Kantonsspital

    Affiliation as printed

    Department of Orthopaedic and Trauma Surgery, Cantonal Hospital Lucerne , Lucerne, Switzerland

  7. Luzerner Kantonsspital

    Affiliation as printed

    Department of Orthopaedic and Trauma Surgery, Cantonal Hospital Lucerne , Lucerne, Switzerland

  8. Luzerner Kantonsspital

    Affiliation as printed

    Department of Orthopaedic and Trauma Surgery, Cantonal Hospital Lucerne , Lucerne, Switzerland

  9. Universitätsklinikum Aachen

    Affiliation as printed

    Department of Radiology, Aachen University Hospital , Aachen, Germany

  10. Universitätsklinikum des Saarlandes · Saarland University

    Affiliation as printed

    Department of Orthopaedic and Traumatology, Saarland University Hospital , Homburg, Germany

  11. Alfried Krupp Hospital

    Affiliation as printed

    Department of Orthopaedic and Traumatology, Alfried Krupp Hospital , Essen, Germany

  12. AO Foundation

    Affiliation as printed

    AO Research Institute Davos Biomechanical Development, , Davos, Switzerland

  13. Luzerner Kantonsspital

    Affiliation as printed

    Department of Orthopaedic and Trauma Surgery, Cantonal Hospital Lucerne , Lucerne, Switzerland

Cited by 1 stored of 1

1 result

No patents citing this paper on Lens.org (checked 2026-10-06).

References 0