Anatomical analysis of different helical plate designs for proximal humeral shaft fracture fixation
British journal of surgery, vol. 109
Abstract
Abstract Objective Helical plates are preferably used for proximal humeral shaft fracture fixation with metaphyseal extension into the humeral head and potentially avoid radial nerve irritation as compared to straight plates. The aims of this study were: (1) to investigate the safety of applying different long plate designs (straight, 45°-, 90°-helical and ALPS) in MIPO-technique to the humerus and (2) to assess and compare their distances to adjacent anatomical structures at risk. Methods MIPO was performed in 16 human cadaveric humeri using either a straight plate (group1), a 45°-helical (group2), a 90°-helical (group3) or an ALPS (group4). Using CT-angiography, distances between brachial arteries and plates were evaluated. Following, all specimens were dissected, and distances to the axillary, radial and musculocutaneous nerve were evaluated. Results None of the specimens demonstrated injuries of the anatomical structures at risk after MIPO with all investigated plate designs. Closest overall distance (mm(range)) between each plate and the radial nerve was 1(1–3) in group1, 7(2–11) in group2, 14(7–25) in group3 and 6(3–8) in group4. It was significantly longer in group3 and significantly shorter in group1 as compared to all other groups, p<0.001. Closest overall distance (mm(range)) between each plate and the musculocutaneous nerve was 16(8–28) in group1, 11(7–18) in group2, 3(2–4) in group3 and 6(3–8) in group4. It was significantly longer in group1 and significantly shorter in group3 as compared to all other groups, p<0.001. Closest overall distance (mm(range)) between each plate and the brachial artery was 21(18–23) in group1, 7(6–7) in group2, 4(3–5) in group3 and 7(6–7) in group4. It was significantly longer in group1 and significantly shorter in group3 as compared to all other groups, p<0.021. Conclusion MIPO with 45°- and 90°-helical plates as well as ALPS is safely feasible and showed a significant greater distance to the radial nerve compared to straight plates. However, distances remain low, and attention must be paid to the musculocutaneous nerve and the brachial artery when MIPO is used with ALPS, 45°- and 90°-helical implants. Moreover, the anterior part of the deltoid insertion will be detached when using 90°-helical and ALPS implants in MIPO-technique.
Authors 13
-
Luzerner Kantonsspital · AO Foundation
Affiliation as printed
AO Research Institute Davos Biomechanical Development, , Davos, Switzerland
Department of Orthopaedic and Trauma Surgery, Cantonal Hospital Lucerne , Lucerne, Switzerland
-
Affiliation as printed
AO Research Institute Davos Biomechanical Development, , Davos, Switzerland
-
Affiliation as printed
AO Research Institute Davos Biomechanical Development, , Davos, Switzerland
-
Affiliation as printed
AO Research Institute Davos Biomechanical Development, , Davos, Switzerland
-
RWTH Aachen University · Universitätsklinikum Aachen
Affiliation as printed
Department of Orthopaedic and Traumatology, Aachen University Hospital , Aachen, Germany
-
Affiliation as printed
Department of Orthopaedic and Trauma Surgery, Cantonal Hospital Lucerne , Lucerne, Switzerland
-
Affiliation as printed
Department of Orthopaedic and Trauma Surgery, Cantonal Hospital Lucerne , Lucerne, Switzerland
-
Affiliation as printed
Department of Orthopaedic and Trauma Surgery, Cantonal Hospital Lucerne , Lucerne, Switzerland
-
Affiliation as printed
Department of Radiology, Aachen University Hospital , Aachen, Germany
-
Universitätsklinikum des Saarlandes · Saarland University
Affiliation as printed
Department of Orthopaedic and Traumatology, Saarland University Hospital , Homburg, Germany
-
Affiliation as printed
Department of Orthopaedic and Traumatology, Alfried Krupp Hospital , Essen, Germany
-
Affiliation as printed
AO Research Institute Davos Biomechanical Development, , Davos, Switzerland
-
Affiliation as printed
Department of Orthopaedic and Trauma Surgery, Cantonal Hospital Lucerne , Lucerne, Switzerland
Cited by 1 stored of 1
1 result
No patents citing this paper on Lens.org (checked 2026-10-06).