Refinement of Dynamic Non-Residential Building Archetypes Using Measurement Data and Bayesian Calibration
Building Simulation Conference proceedings, vol. 16, pp. 4682–4689
Abstract
Dynamic simulation and optimization of energy systems at urban level becomes increasingly important as an additional decision criteria for planning and operation. Essential in this context is the dynamic heating and cooling demand of buildings. Often building archetypes are used to depict the individual characteristics of buildings. While in average the demand is accurately reproduced by archetype buildings, individual buildings deviate from the statistical average. This paper presents a methodology to refine building archetypes using real measurement data and Bayesian Calibration. The calibration uses statistical indices instead of whole time series or yearly cumulated energy demands. We apply the methodology to four real buildings, the results demonstrate the potential of the methodology by reducing the RMSE between measured and simulated heating demand up to 57 %.
Authors 2
-
Affiliation as printed
RWTH Aachen University , E.ON Energy Research Center ,
Institute for Energy Efficient Buildings and Indoor Climate, Germany
RWTH Aachen University, E.ON Energy Research Center,
-
Affiliation as printed
RWTH Aachen University , E.ON Energy Research Center ,
Institute for Energy Efficient Buildings and Indoor Climate, Germany
RWTH Aachen University, E.ON Energy Research Center,
Cited by 3 stored of 3
3 results
No patents citing this paper on Lens.org (checked 2026-10-06).
References 32
-
W6675354045details pending0citations
-
W2806377715details pending0citations
-
W1788054578details pending0citations