Influence of oral anticoagulation on success rates and risk of bleeding events after iStent inject implantation combined with phacoemulsification
Graefe s Archive for Clinical and Experimental Ophthalmology, vol. 258, pp. 2483–2487
Abstract
PURPOSE: We conducted a retrospective study to evaluate the intraocular pressure (IOP) lowering effect, the success rates, and the risk of bleeding events of patients receiving an iStent inject combined with phacoemulsification under anticoagulation therapy compared with a matched control group. METHODS: In this retrospective study, sixty-four eyes underwent an iStent inject implantation combined with phacoemulsification at two centers. Thirty-two eyes received surgery while under anticoagulation therapy, and another thirty-two eyes served as a control group matched for visual acuity, IOP, and medication score. Success was defined as criteria A and B (IOP < 18/21 mmHg, > 20% IOP reduction, no resurgery) and criteria C (IOP ≤ 15 mmHg, IOP reduction ≥ 40%, no resurgery). The clinical goal of the study was to determine the difference between the study and control groups with respect to IOP, medication score, and the frequency of intraoperative and postoperative bleeding events. RESULTS: After a mean follow-up time of 1 year, the IOP lowered 28% from 20.1 ± 4.8 to 14.5 ± 3.7 mmHg in the group of 64 eyes. The medication score lowered 38% from 2.1 ± 1.1 to 1.3 ± 1.2. The two groups with and without anticoagulant agents did not significantly differ in postoperative IOP, medication score, success rates, or number of bleeding events. CONCLUSION: We conclude that in cataract surgery combined with the iStent inject a discontinuation of anticoagulant agents might not be necessary. It might be a good option in glaucoma surgery when anticoagulation treatment should not be interrupted and the target pressure is not very low.
Authors 6
-
Randolf Alexander Widder corresponding
Affiliation as printed
Center of Ophthalmology, University of Cologne, Kerpener Strasse 62, 50937, Köln, Germany. r.widder@martinus-duesseldorf.de
Department of Ophthalmology, St. Martinus-Krankenhaus Düsseldorf, Gladbacher Strasse 26, 40219, Düsseldorf, Germany. r.widder@martinus-duesseldorf.de
Department of Ophthalmology, St. Martinus-Krankenhaus Düsseldorf, Gladbacher Strasse 26, 40219, Düsseldorf, Germany
-
Affiliation as printed
Center of Ophthalmology, University of Cologne, Kerpener Strasse 62, 50937, Köln, Germany
-
Affiliation as printed
Department of Ophthalmology, St. Martinus-Krankenhaus Düsseldorf, Gladbacher Strasse 26, 40219, Düsseldorf, Germany
-
Affiliation as printed
Department of Ophthalmology, St. Martinus-Krankenhaus Düsseldorf, Gladbacher Strasse 26, 40219, Düsseldorf, Germany
-
Affiliation as printed
Department of Ophthalmology, RWTH Aachen, Pauwelsstrasse 30, 52074, Aachen, Germany
Department of Ophthalmology, St. Martinus-Krankenhaus Düsseldorf, Gladbacher Strasse 26, 40219, Düsseldorf, Germany
-
Affiliation as printed
Center of Ophthalmology, University of Cologne, Kerpener Strasse 62, 50937, Köln, Germany
Cited by 9 stored of 9
9 results
No patents citing this paper on Lens.org (checked 2026-10-06).
References 13
-
W2085815830details pending0citations
-
W2227600151details pending0citations
-
W1998957210details pending0citations
-
W2330484787details pending0citations
-
W2509820146details pending0citations
-
W2510234857details pending0citations
-
W2518015813details pending0citations
-
W2768962386details pending0citations
-
W2776670708details pending0citations
-
W2921386357details pending0citations
-
W2943482476details pending0citations
-
W2946723174details pending0citations
-
W2973854754details pending0citations
13 results