Cross-site investigation on head-related and headphone transfer functions: variabilities in relation to loudness balancing
Acta Acustica, vol. 5, pp. 58
Abstract
Headphone transfer function (HpTF) and head-related transfer function (HRTF) measurements are crucial in acoustic science and in binaural virtual acoustic applications. Yet, their measurement set-up, procedure or post-processing is different for nearly every lab, especially for the HRTF measurements. To compare findings between different labs, these measurement deviations have to be quantified alongside with their influence on perceptual aspects. In the scope of a cross-site investigation on loudness balancing between headphone and loudspeaker listening, a set of HpTFs with three different headphones (open, closed, insert earphones) and HRTF close to the eardrum were measured in 14 participants travelling to two different measurement sites at Aachen and Oldenburg. Though set-ups for measuring the HRTF are very different between sites, the gathered HRTFs are quite consistent across them. For the measured HpTFs, across sites the open headphones consistently yield a slightly lower variability in the range from 70 to 5000 Hz than the closed one while the insert earphones exhibit much higher variabilities and a limited range of reproducible results. The difference in loudness balancing across labs could well be predicted by site-specific systematic differences in HpTFs with the exception of 1 kHz narrowband stimulus. This clearly indicates the limits in comparability of HpTFs and loudness balancing across labs and the importance of using headphones with high repeatability like the open ones used in this investigation.
Authors 5
-
Affiliation as printed
Institute for Hearing Technology and Acoustics, RWTH Aachen University, 52056 Aachen, Germany
-
Carl von Ossietzky Universität Oldenburg · Hearing4all
Affiliation as printed
Medizinische Physik & Cluster of Excellence Hearing4All, Universität Oldenburg, 26111 Oldenburg, Germany
Now at: German Institute of Hearing Aids, Anschützsraϐe 1, 23562 Lübeck, Germany
-
Affiliation as printed
Institute for Hearing Technology and Acoustics, RWTH Aachen University, 52056 Aachen, Germany
-
Carl von Ossietzky Universität Oldenburg · Hearing4all
Affiliation as printed
Medizinische Physik & Cluster of Excellence Hearing4All, Universität Oldenburg, 26111 Oldenburg, Germany
-
Affiliation as printed
Institute for Hearing Technology and Acoustics, RWTH Aachen University, 52056 Aachen, Germany
Cited by 1 stored of 1
1 result
No patents citing this paper on Lens.org (checked 2026-10-06).
References 19
-
W4213129550details pending0citations
-
W2028115554details pending0citations
-
W3044194010details pending0citations
-
W1846237574details pending0citations
-
W1968606725details pending0citations
-
W2086928746details pending0citations
-
W2790564967details pending0citations
-
W2141641465details pending0citations
-
W2102208671details pending0citations
-
W1991430067details pending0citations
-
W2038684692details pending0citations
-
W2120390344details pending0citations
-
W4249422042details pending0citations
19 results