Cycloidal CT with CNN-based sinogram completion and in-scan generation of training data
Scientific Reports, vol. 12, pp. 893
Abstract
In x-ray computed tomography (CT), the achievable image resolution is typically limited by several pre-fixed characteristics of the x-ray source and detector. Structuring the x-ray beam using a mask with alternating opaque and transmitting septa can overcome this limit. However, the use of a mask imposes an undersampling problem: to obtain complete datasets, significant lateral sample stepping is needed in addition to the sample rotation, resulting in high x-ray doses and long acquisition times. Cycloidal CT, an alternative scanning scheme by which the sample is rotated and translated simultaneously, can provide high aperture-driven resolution without sample stepping, resulting in a lower radiation dose and faster scans. However, cycloidal sinograms are incomplete and must be restored before tomographic images can be computed. In this work, we demonstrate that high-quality images can be reconstructed by applying the recently proposed Mixed Scale Dense (MS-D) convolutional neural network (CNN) to this task. We also propose a novel training approach by which training data are acquired as part of each scan, thus removing the need for large sets of pre-existing reference data, the acquisition of which is often not practicable or possible. We present results for both simulated datasets and real-world data, showing that the combination of cycloidal CT and machine learning-based data recovery can lead to accurate high-resolution images at a limited dose.
Authors 5
-
Affiliation as printed
Leiden Institute of Advanced Computer Science, Leiden University, Niels Bohrweg 1, 2333, CA, Leiden, The Netherlands. d.m.pelt@liacs.leidenuniv.nl
Leiden Institute of Advanced Computer Science, Leiden University, Niels Bohrweg 1, 2333, CA, Leiden, The Netherlands
-
Affiliation as printed
Department of Medical Physics and Biomedical Engineering, University College London, Malet Place, London, WC1E 6BT, UK
-
Affiliation as printed
Department of Medical Physics and Biomedical Engineering, University College London, Malet Place, London, WC1E 6BT, UK
-
Affiliation as printed
Department of Medical Physics and Biomedical Engineering, University College London, Malet Place, London, WC1E 6BT, UK
-
Affiliation as printed
Department of Medical Physics and Biomedical Engineering, University College London, Malet Place, London, WC1E 6BT, UK
Cited by 5 stored of 5
5 results
No patents citing this paper on Lens.org (checked 2026-10-11).