An accelerometer-based guidance device for CT-guided procedures: an improved wireless prototype
Minimally Invasive Therapy & Allied Technologies, vol. 31, pp. 902–908
Abstract
Introduction The aim of the study was to demonstrate the feasibility of a prototype for accelerometer-based guidance for percutaneous CT-guided punctures and compare it with free-hand punctures.Material and methods The prototype enabled alignment with the CT coordinate system and a wireless connectivity. Its feasibility was tested in a swine cadaver model: 20 out-of-plane device-assisted punctures performed without intermittent control scans (one-step punctures) were evaluated regarding deviation to target and difference between planned and obtained angle. Thereafter, 22 device-assisted punctures were compared with 20 free-hand punctures regarding distance to target, deviation from the planned angle, number of control scans and procedure time. Differences were compared with the Mann–Whitney U-test (p < .05).Results The one-step punctures revealed a deviation to target of 0.26 ± 0.37 cm (axial plane) and 0.21 ± 0.19 cm (sagittal plane) and differences between planned and performed puncture angles of 0.9 ± 1.09° (axial plane) and 1.15 ± 0.91° (sagittal planes). In the comparative study, device-assisted punctures showed a significantly higher accuracy, 0.20 ± 0.17 cm vs. 0.30 ± 0.21 cm (p < .05) and lower number of required control scans, 1.3 ± 1.1 vs. 3.7 ± 0.9 (p < .05) compared with free-hand punctures.Conclusion The accelerometer-based device proved to be feasible and demonstrated significantly higher accuracy and required significantly less control scans compared to free-hand puncture.
Authors 8
-
Universitätsklinikum Aachen · RWTH Aachen University
Affiliation as printed
Department of Diagnostic and Interventional Radiology, RWTH Aachen University Hospital, Aachen, Germany
-
Christoph Wilkmann Aachen Department of Diagnostic and Interventional Radiology Institute of Applied Medical Engineering
Universitätsklinikum Aachen · RWTH Aachen University
Affiliation as printed
Department of Diagnostic and Interventional Radiology, RWTH Aachen University Hospital, Aachen, Germany
Institute of Applied Medical Engineering, Deptartment of Rehabilitation & Prevention Engineering, RWTH Aachen University, Aachen, Germany
-
Berlin Institute of Health at Charité - Universitätsmedizin Berlin · Charité - Universitätsmedizin Berlin
Affiliation as printed
Berlin Institute of Health, Berlin, Germany
Department of Radiology, Charité Universitätsmedizin Berlin, Berlin, Germany
-
Affiliation as printed
Institute of Applied Medical Engineering, Deptartment of Rehabilitation & Prevention Engineering, RWTH Aachen University, Aachen, Germany
-
Affiliation as printed
Institute of Applied Medical Engineering, Deptartment of Rehabilitation & Prevention Engineering, RWTH Aachen University, Aachen, Germany
-
Universitätsklinikum Aachen · RWTH Aachen University
Affiliation as printed
Department of Diagnostic and Interventional Radiology, RWTH Aachen University Hospital, Aachen, Germany
-
Universitätsklinikum Aachen · RWTH Aachen University
Affiliation as printed
Department of Diagnostic and Interventional Radiology, RWTH Aachen University Hospital, Aachen, Germany
-
Universitätsklinikum Aachen · RWTH Aachen University
Affiliation as printed
Department of Diagnostic and Interventional Radiology, RWTH Aachen University Hospital, Aachen, Germany
Cited by 0 stored of 0
No patents citing this paper on Lens.org (checked 2026-10-06).
References 19
19 results