Towards X-ray Plenoptic Imaging: Emulation with a Laboratory X-ray Scanner
Abstract
X-ray plenoptic apparatuses acquire multi-view single-shot radiographs, but their development is challenging. We present a physical emulation setup for rapidly and inexpensively exploring their design parameter-space, that only uses a flexible laboratory X-ray scanner.
Authors 8
-
Nicola Viganò corresponding
Centrum Wiskunde & Informatica · European Synchrotron Radiation Facility
Affiliation as printed
Centrum Wiskunde & Informatica (CWI), NWO, 1098 XG Amsterdam, The Netherlands
ESRF—The European Synchrotron, 38043 Grenoble, France
-
Felix F. Lucka corresponding
Centrum Wiskunde & Informatica · University College London
Affiliation as printed
Centre for Medical Image Computing, University College London, London WC1V 6LJ, UK
Centrum Wiskunde & Informatica (CWI), NWO, 1098 XG Amsterdam, The Netherlands
-
Ombeline de La Rochefoucauld corresponding
Affiliation as printed
Imagine Optic, 33400 Talence, France
-
Sophia Bethany Coban corresponding
Centrum Wiskunde & Informatica
Affiliation as printed
Centrum Wiskunde & Informatica (CWI), NWO, 1098 XG Amsterdam, The Netherlands
-
Robert van Liere corresponding
Centrum Wiskunde & Informatica · Eindhoven University of Technology
Affiliation as printed
Centrum Wiskunde & Informatica (CWI), NWO, 1098 XG Amsterdam, The Netherlands
Mathematics and Computer Science, Technical University Eindhoven, 5600 MB Eindhoven, The Netherlands
-
Marta Fajardo corresponding
University of Lisbon · Instituto Superior Técnico · Instituto de Plasmas e Fusão Nuclear
Affiliation as printed
Instituto de Plasmas e Fusão Nuclear, Instituto Superior Técnico, Universidade de Lisboa, 1049-001 Lisboa, Portugal
-
Philippe Zeitoun corresponding
Centre National de la Recherche Scientifique · École Nationale Supérieure de Techniques Avancées · Laboratoire d'Optique Appliquée · Institut Polytechnique de Paris
Affiliation as printed
Laboratoire d’Optique Appliquée, ENSTA, CNRS, Institut Polytechnique Paris, 91762 Palaiseau, France
Laboratoire d'Optique Appliquée, ENSTA, CNRS, Institut Polytechnique Paris, 91762 Palaiseau, France
-
Leiden University · Centrum Wiskunde & Informatica
Affiliation as printed
Centrum Wiskunde & Informatica (CWI), NWO, 1098 XG Amsterdam, The Netherlands
Leiden Institute of Advanced Computer Science, Leiden University, 2333 CA Leiden, The Netherlands
Cited by 0 stored of 0
No patents citing this paper on Lens.org (checked 2026-10-11).
References 6
-
W3098920738details pending0citations
6 results