A

Optimal Designed Experiments for Reliable Model Calibration of a fixed-speed Scroll Compressor with R410A and R32

IOP Conference Series Materials Science and Engineering, vol. 1180, pp. 012032

Abstract

Abstract Mainly to provide heat, the building sector accounts for about 18 % of overall global CO2 emissions. By exchanging conventional technologies in the near future, heat pumps are a key technology to systematically decarbonise the heat supply chain. The efficiency of a heat pump strongly depends on its compressor’s efficiency. Thus, the compressor is the subject of current research. The compressor performance depends on the fluid with its inlet and outlet conditions, an appropriate oil, and the mechanic compression principle. Based on that, the performance is expressed by the isentropic and volumetric efficiency. To describe a compressor in detail and fluid independent is challenging. Therefore, many theoretical studies have been conducted, while in comparison experimental studies are rare. To overcome this imbalance, this study focuses a detailed experimental investigation of a 4 kW Copeland scroll compressor with R410A and R32 on a fully automated compressor test stand. Within this paper, we present a method for in-depth uncertainty analysis, which ensures the usability and comparability of our experimental results to other experiments. We store our results in optimal calibrated simulation models based on optimal experimental design. This allows us to reduce experimental effort up to 70 % compared to full factorial experimental designs. To prove the method in a compressor and two fluids, we apply it to a fixed-speed scroll compressor with R410A and R32. The test stand is able to conduct all experiments automatically and part load behaviour of both refrigerants can be summarized in a model according to recent Literature with an overall uncertainty below 8 % for R410A. For R32, the method fails. Utilizing this method, we aim at open-source experiments in order to accelerate the solution of complex research questions.

Authors 5

  1. RWTH Aachen University

    Affiliation as printed

    RWTH Aachen University, Institute for Energy Efficient Buildings and Indoor Climate, Mathieustraβe 10, 52074 Aachen, Germany

  2. RWTH Aachen University

    Affiliation as printed

    RWTH Aachen University, Institute for Energy Efficient Buildings and Indoor Climate, Mathieustraβe 10, 52074 Aachen, Germany

  3. RWTH Aachen University

    Affiliation as printed

    RWTH Aachen University, Institute for Energy Efficient Buildings and Indoor Climate, Mathieustraβe 10, 52074 Aachen, Germany

  4. RWTH Aachen University

    Affiliation as printed

    RWTH Aachen University, Institute for Energy Efficient Buildings and Indoor Climate, Mathieustraβe 10, 52074 Aachen, Germany

  5. RWTH Aachen University

    Affiliation as printed

    RWTH Aachen University, Institute for Energy Efficient Buildings and Indoor Climate, Mathieustraβe 10, 52074 Aachen, Germany

Cited by 1 stored of 1

1 result

No patents citing this paper on Lens.org (checked 2026-10-06).

References 11

11 results