Exploring the potential of cycloidal computed tomography for advancing intraoperative specimen imaging

Abstract

A preliminary investigation into the use of cycloidal computed tomography for intraoperative specimen imaging is presented. Intraoperative imaging is applied in time-sensitive clinical settings, where obtaining a high-resolution, highquality image within minutes is paramount in evaluating the success of operations and/or the need for additional surgery. As a flexible imaging method that is compatible with x-ray phase contrast imaging, cycloidal computed tomography can provide both high spatial resolution and high image contrast, whilst keeping scan times short thanks to an effective under-sampling approach. To gather early evidence, the method was tested on resected breast and oesophageal tissue. The results, although preliminary, indicate that cycloidal imaging may indeed be beneficial for intraoperative specimen imaging, although further studies are required to confirm this potential.

Authors 15

  1. University College London

    Affiliation as printed

    Univ. College London (United Kingdom)

  2. University College London

    Affiliation as printed

    Univ. College London (United Kingdom)

  3. St Bartholomew's Hospital

    Affiliation as printed

    St. Bartholomew's Hospital (United Kingdom)

  4. University College London

    Affiliation as printed

    Univ. College London (United Kingdom)

  5. University College London

    Affiliation as printed

    Univ. College London (United Kingdom)

  6. University College London

    Affiliation as printed

    Univ. College London (United Kingdom)

  7. Nikon (United Kingdom)

    Affiliation as printed

    Nikon Metrology UK Ltd. (United Kingdom)

  8. Nikon (United Kingdom)

    Affiliation as printed

    Nikon Metrology UK Ltd. (United Kingdom)

  9. Nikon (United Kingdom)

    Affiliation as printed

    Nikon Metrology UK Ltd. (United Kingdom)

  10. Queen Mary University of London

    Affiliation as printed

    Barts and The London School of Medicine and Dentistry (United Kingdom)

  11. St Bartholomew's Hospital · Queen Mary University of London

    Affiliation as printed

    Barts and The London School of Medicine and Dentistry (United Kingdom)

    St. Bartholomew's Hospital (United Kingdom)

  12. Leiden University

    Affiliation as printed

    Leiden Institute of Advanced Computer Science (Netherlands)

  13. Nikon (United Kingdom) · University College London

    Affiliation as printed

    Nikon Metrology UK Ltd. (United Kingdom)

    Univ. College London (United Kingdom)

  14. University College London

    Affiliation as printed

    Univ. College London (United Kingdom)

  15. University College London

    Affiliation as printed

    Univ. College London (United Kingdom)

Cited by 3 stored of 3

3 results

No patents citing this paper on Lens.org (checked 2026-10-11).

References 33