Defining corneal chemical burns: A novel exact and adjustable ocular model
Toxicology Reports, vol. 8, pp. 1200–1206
Abstract
Live-animal-free ocular toxicity models and tests are a necessity in multiple branches of medicine, industry and science. Corneal models with adjustable ranges of injury severities do not exist. In this work, a novel and precise and dose - response method to induce and observe ex vivo corneal chemical burns has been established. The EVEIT (Ex Vivo Eye Irritation Test) is based on an ex vivo corneal organ model for rabbit corneas from food industry. Further, a highly precise three – axis workstation has been employed to apply liquid corrosive, sodium hydroxide (NaOH), droplets in a nanolitre (nL) range onto the corneal surface. Optical Coherence Tomography (OCT) has been used to observe and quantify the elicited changes in the corneal layers. The speed and intervals of single nanodroplet application played a crucial role in the extent of the corneal changes. Similar total volumes applied at low frequencies elicited deep and extensive changes in the corneal layers whereas high application frequencies elicited comparatively superficial changes. Increasing NaOH concentrations effected measurably increasing corneal changes. Increasing the volume of applied NaOH also showed an increase in corneal changes. OCT imaging proved to be effective in observing, documenting and quantifying the changes in the corneal layers. The ex vivo model, in conjunction with the novel application method was able to induce and display distinctive and consistent correlations between NaOH volume, concentration and elicited corneal changes. This ex vivo ocular chemical burn model provides a consistent in vitro basis for pharmaceutical and toxicological experiments and investigations into corneal chemical burn mechanisms and treatment.
Authors 3
-
Markus Glaudo corresponding Aachen Aachen Centre of Technology Transfer in Ophthalmology (ACTO e.V.)
Aachener Centrum für Technologietransfer in der Ophthalmologie
Affiliation as printed
Aachen Centre of Technology Transfer in Ophthalmology, (ACTO e. V.) Karlsburgweg 9, 52070 Aachen, Germany
-
Aachener Centrum für Technologietransfer in der Ophthalmologie
Affiliation as printed
Aachen Centre of Technology Transfer in Ophthalmology, (ACTO e. V.) Karlsburgweg 9, 52070 Aachen, Germany
-
Aachener Centrum für Technologietransfer in der Ophthalmologie
Affiliation as printed
Aachen Centre of Technology Transfer in Ophthalmology, (ACTO e. V.) Karlsburgweg 9, 52070 Aachen, Germany
Cited by 3 stored of 3
3 results
No patents citing this paper on Lens.org (checked 2026-10-06).
References 13
-
W2131235720details pending0citations
-
W2411125938details pending0citations
-
W189381086details pending0citations
-
W1502075302details pending0citations
-
W1981757193details pending0citations
-
W1994674706details pending0citations
-
W2054575223details pending0citations
-
W2076111934details pending0citations
-
W2100585541details pending0citations
-
W2142283596details pending0citations
-
W6607878154details pending0citations
-
W6629752776details pending0citations
13 results