Efficient high cone-angle artifact reduction in circular cone-beam CT using deep learning with geometry-aware dimension reduction

Physics in Medicine and Biology, vol. 66, pp. 135015

Abstract

High cone-angle artifacts (HCAAs) appear frequently in circular cone-beam computed tomography (CBCT) images and can heavily affect diagnosis and treatment planning. To reduce HCAAs in CBCT scans, we propose a novel deep learning approach that reduces the three-dimensional (3D) nature of HCAAs to two-dimensional (2D) problems in an efficient way. Specifically, we exploit the relationship between HCAAs and the rotational scanning geometry by training a convolutional neural network (CNN) using image slices that were radially sampled from CBCT scans. We evaluated this novel approach using a dataset of input CBCT scans affected by HCAAs and high-quality artifact-free target CBCT scans. Two different CNN architectures were employed, namely U-Net and a mixed-scale dense CNN (MS-D Net). The artifact reduction performance of the proposed approach was compared to that of a Cartesian slice-based artifact reduction deep learning approach in which a CNN was trained to remove the HCAAs from Cartesian slices. In addition, all processed CBCT scans were segmented to investigate the impact of HCAAs reduction on the quality of CBCT image segmentation. We demonstrate that the proposed deep learning approach with geometry-aware dimension reduction greatly reduces HCAAs in CBCT scans and outperforms the Cartesian slice-based deep learning approach. Moreover, the proposed artifact reduction approach markedly improves the accuracy of the subsequent segmentation task compared to the Cartesian slice-based workflow.

Authors 9

  1. Jordi Minnema corresponding

    Academic Center for Dentistry Amsterdam · Amsterdam University Medical Centers · Amsterdam Movement Sciences · Vrije Universiteit Amsterdam

    Affiliation as printed

    Vrije Universiteit Amsterdam

    Amsterdam UMC and Academic Centre for Dentistry Amsterdam (ACTA), Vrije Universiteit Amsterdam, Department of Oral and Maxillofacial Surgery/Pathology, 3D Innovationlab, Amsterdam Movement Sciences, 1081 HV Amsterdam, The Netherlands

  2. Centrum Wiskunde & Informatica · Eindhoven University of Technology

    Affiliation as printed

    Centrum Wiskunde & Informatica (CWI), 1090 GB Amsterdam,

    Eindhoven University of Technology

    Centrum Wiskunde & Informatica (CWI), 1090 GB Amsterdam, The Netherlands

    Medical Image Analysis Group, Department of Biomedical Engineering, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven, The Netherlands

  3. Centrum Wiskunde & Informatica

    Affiliation as printed

    Centrum Wiskunde & Informatica (CWI), 1090 GB Amsterdam,

    Centrum Wiskunde & Informatica (CWI), 1090 GB Amsterdam, The Netherlands

  4. Centrum Wiskunde & Informatica

    Affiliation as printed

    Centrum Wiskunde & Informatica (CWI), 1090 GB Amsterdam,

    Centrum Wiskunde & Informatica (CWI), 1090 GB Amsterdam, The Netherlands

  5. University of Helsinki

    Affiliation as printed

    University of Helsinki

    Department of Physics, University of Helsinki, Gustaf Hällsströmin katu 2, FI-00560, Helsinki, Finland

  6. Aarhus University · University Medical Center Hamburg-Eppendorf · Fraunhofer Research Institution for Additive Manufacturing Technologies IAPT

    Affiliation as printed

    Aarhus University

    Fraunhofer Research Institution for Additive Manufacturing Technologies IAPT, Am Schleusengraben 13, D-21029 Hamburg,

    University Hospital

    Department of Dentistry and Oral Health, Aarhus University, Vennelyst Boulevard 9, DK-8000 Aarhus C, Denmark

    Department of Oral and Maxillofacial Surgery, Division for Regenerative Orofacial Medicine, University Hospital Hamburg-Eppendorf, 20246 Hamburg, Germany

    Fraunhofer Research Institution for Additive Manufacturing Technologies IAPT, Am Schleusengraben 13,21029 Hamburg, Germany

  7. Academic Center for Dentistry Amsterdam · Amsterdam University Medical Centers · Amsterdam Movement Sciences · Vrije Universiteit Amsterdam

    Affiliation as printed

    Vrije Universiteit Amsterdam

    Amsterdam UMC and Academic Centre for Dentistry Amsterdam (ACTA), Vrije Universiteit Amsterdam, Department of Oral and Maxillofacial Surgery/Pathology, 3D Innovationlab, Amsterdam Movement Sciences, 1081 HV Amsterdam, The Netherlands

  8. Centrum Wiskunde & Informatica · University College London

    Affiliation as printed

    Centrum Wiskunde & Informatica (CWI), 1090 GB Amsterdam,

    University College London

    Centre for Medical Image Computing, University College London, WC1E 6BT London, United Kingdom

    Centrum Wiskunde & Informatica (CWI), 1090 GB Amsterdam, The Netherlands

  9. Leiden University · Centrum Wiskunde & Informatica

    Affiliation as printed

    Centrum Wiskunde & Informatica (CWI), 1090 GB Amsterdam,

    Leiden University

    Centrum Wiskunde & Informatica (CWI), 1090 GB Amsterdam, The Netherlands

    Leiden Institute of Advanced Computer Science (LIACS), Leiden University, 2333 CA Leiden, The Netherlands

Cited by 5 stored of 5

5 results

No patents citing this paper on Lens.org (checked 2026-10-11).

References 46