Quantitative Comparison of Deep Learning-Based Image Reconstruction Methods for Low-Dose and Sparse-Angle CT Applications

Journal of Imaging, vol. 7, pp. 44

Abstract

The reconstruction of computed tomography (CT) images is an active area of research. Following the rise of deep learning methods, many data-driven models have been proposed in recent years. In this work, we present the results of a data challenge that we organized, bringing together algorithm experts from different institutes to jointly work on quantitative evaluation of several data-driven methods on two large, public datasets during a ten day sprint. We focus on two applications of CT, namely, low-dose CT and sparse-angle CT. This enables us to fairly compare different methods using standardized settings. As a general result, we observe that the deep learning-based methods are able to improve the reconstruction quality metrics in both CT applications while the top performing methods show only minor differences in terms of peak signal-to-noise ratio (PSNR) and structural similarity (SSIM). We further discuss a number of other important criteria that should be taken into account when selecting a method, such as the availability of training data, the knowledge of the physical measurement model and the reconstruction speed.

Authors 11

  1. Johannes Leuschner corresponding

    University of Bremen

    Affiliation as printed

    Center for Industrial Mathematics, University of Bremen, Bibliothekstr. 5, 28359 Bremen, Germany

  2. University of Bremen

    Affiliation as printed

    Center for Industrial Mathematics, University of Bremen, Bibliothekstr. 5, 28359 Bremen, Germany

  3. Leiden University · Centrum Wiskunde & Informatica

    Affiliation as printed

    Centrum Wiskunde & Informatica, Science Park 123, 1098 XG Amsterdam, The Netherlands

    The Mathematical Institute, Leiden University, Niels Bohrweg 1, 2333 CA Leiden, The Netherlands

  4. Centrum Wiskunde & Informatica

    Affiliation as printed

    Centrum Wiskunde & Informatica, Science Park 123, 1098 XG Amsterdam, The Netherlands

  5. Centrum Wiskunde & Informatica

    Affiliation as printed

    Centrum Wiskunde & Informatica, Science Park 123, 1098 XG Amsterdam, The Netherlands

  6. University of Bremen

    Affiliation as printed

    Center for Industrial Mathematics, University of Bremen, Bibliothekstr. 5, 28359 Bremen, Germany

  7. Heidelberg University

    Affiliation as printed

    Computer Assisted Clinical Medicine, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany

  8. University of British Columbia

    Affiliation as printed

    School of Biomedical Engineering, University of British Columbia, 2222 Health Sciences Mall, Vancouver, BC V6T 1Z3, Canada

  9. Leiden University · Centrum Wiskunde & Informatica

    Affiliation as printed

    Centrum Wiskunde & Informatica, Science Park 123, 1098 XG Amsterdam, The Netherlands

    Leiden Institute of Advanced Computer Science, Niels Bohrweg 1, 2333 CA Leiden, The Netherlands

  10. University of Bremen

    Affiliation as printed

    Center for Industrial Mathematics, University of Bremen, Bibliothekstr. 5, 28359 Bremen, Germany

  11. Centrum Wiskunde & Informatica · Eindhoven University of Technology

    Affiliation as printed

    Centrum Wiskunde & Informatica, Science Park 123, 1098 XG Amsterdam, The Netherlands

    Department of Biomedical Engineering, Eindhoven University of Technology, Groene Loper 3, 5612 AE Eindhoven, The Netherlands

Cited by 53 stored of 53

No patents citing this paper on Lens.org (checked 2026-10-11).

References 101