Quantitative Comparison of Deep Learning-Based Image Reconstruction Methods for Low-Dose and Sparse-Angle CT Applications
Journal of Imaging, vol. 7, pp. 44
Abstract
The reconstruction of computed tomography (CT) images is an active area of research. Following the rise of deep learning methods, many data-driven models have been proposed in recent years. In this work, we present the results of a data challenge that we organized, bringing together algorithm experts from different institutes to jointly work on quantitative evaluation of several data-driven methods on two large, public datasets during a ten day sprint. We focus on two applications of CT, namely, low-dose CT and sparse-angle CT. This enables us to fairly compare different methods using standardized settings. As a general result, we observe that the deep learning-based methods are able to improve the reconstruction quality metrics in both CT applications while the top performing methods show only minor differences in terms of peak signal-to-noise ratio (PSNR) and structural similarity (SSIM). We further discuss a number of other important criteria that should be taken into account when selecting a method, such as the availability of training data, the knowledge of the physical measurement model and the reconstruction speed.
Authors 11
-
Johannes Leuschner corresponding
Affiliation as printed
Center for Industrial Mathematics, University of Bremen, Bibliothekstr. 5, 28359 Bremen, Germany
-
Affiliation as printed
Center for Industrial Mathematics, University of Bremen, Bibliothekstr. 5, 28359 Bremen, Germany
-
Leiden University · Centrum Wiskunde & Informatica
Affiliation as printed
Centrum Wiskunde & Informatica, Science Park 123, 1098 XG Amsterdam, The Netherlands
The Mathematical Institute, Leiden University, Niels Bohrweg 1, 2333 CA Leiden, The Netherlands
-
Centrum Wiskunde & Informatica
Affiliation as printed
Centrum Wiskunde & Informatica, Science Park 123, 1098 XG Amsterdam, The Netherlands
-
Centrum Wiskunde & Informatica
Affiliation as printed
Centrum Wiskunde & Informatica, Science Park 123, 1098 XG Amsterdam, The Netherlands
-
Affiliation as printed
Center for Industrial Mathematics, University of Bremen, Bibliothekstr. 5, 28359 Bremen, Germany
-
Affiliation as printed
Computer Assisted Clinical Medicine, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany
-
University of British Columbia
Affiliation as printed
School of Biomedical Engineering, University of British Columbia, 2222 Health Sciences Mall, Vancouver, BC V6T 1Z3, Canada
-
Leiden University · Centrum Wiskunde & Informatica
Affiliation as printed
Centrum Wiskunde & Informatica, Science Park 123, 1098 XG Amsterdam, The Netherlands
Leiden Institute of Advanced Computer Science, Niels Bohrweg 1, 2333 CA Leiden, The Netherlands
-
Affiliation as printed
Center for Industrial Mathematics, University of Bremen, Bibliothekstr. 5, 28359 Bremen, Germany
-
Maureen A.J.M. van Eijnatten corresponding
Centrum Wiskunde & Informatica · Eindhoven University of Technology
Affiliation as printed
Centrum Wiskunde & Informatica, Science Park 123, 1098 XG Amsterdam, The Netherlands
Department of Biomedical Engineering, Eindhoven University of Technology, Groene Loper 3, 5612 AE Eindhoven, The Netherlands
Cited by 53 stored of 53
No patents citing this paper on Lens.org (checked 2026-10-11).