Non‐Cartesian k‐space trajectory calculation based on concurrent reading of the gradient amplifiers’ output currents

Magnetic Resonance in Medicine, vol. 85, pp. 3060–3070

Abstract

PURPOSE: Non-Cartesian imaging sequences involve sampling during rapid variation of the encoding field gradients. The quality of the reconstructed images often suffers from insufficient knowledge of the exact dynamics of the actual fields applied during sampling. METHODS: We propose determination of the accurate field dynamics by measuring the currents at the gradient amplifier outputs using the amplifiers' internal sensors concurrently with imaging. The actual dynamic field evolution is then determined by convolution with the measured current-to-field impulse response function of the gradient coil. Integration of the gradient field evolution allows derivation of the k-space trajectory for reconstruction. RESULTS: The current-based approach is investigated in spiral and ultrashort TE phantom imaging. In comparison with the model-based product reconstruction as well as a correction approach based on the conventional input waveform-to-field impulse response function, it provides slightly improved image quality. The improvement is ascribed to a better representation of eddy current and amplifier nonlinearity effects. CONCLUSION: Trajectory calculation based on measured amplifier output currents offers a robust, purely measurement-based alternative to conventional model-based approaches. The implementation can mitigate gradient amplifier imperfections with no or little additional hardware effort.

Authors 5

  1. Jürgen Rahmer corresponding

    Philips (Germany)

    Affiliation as printed

    Philips Research Hamburg Germany

    Philips Research, Hamburg, Germany

  2. Philips (Germany)

    Affiliation as printed

    Philips Research Hamburg Germany

    Philips Research, Hamburg, Germany

  3. Philips (Germany)

    Affiliation as printed

    Philips Research Hamburg Germany

    Philips Research, Hamburg, Germany

  4. Philips (Germany)

    Affiliation as printed

    Philips Research Hamburg Germany

    Philips Research, Hamburg, Germany

  5. Leiden University Medical Center · Philips (Germany)

    Affiliation as printed

    Philips Research Hamburg Germany

    Radiology, C.J. Gorter Center for High‐Field MRI Leiden University Medical Center Leiden the Netherlands

    Philips Research, Hamburg, Germany

    Radiology, C.J. Gorter Center for High-Field MRI, Leiden University Medical Center, Leiden, the Netherlands

Cited by 11 stored of 11

11 results

References 28