Abstract
Today Time-of-Flight (TOF), in PET scanners, assumes a single, well-defined timing resolution for all events. However, recent BGO-Cherenkov detectors, combining prompt Cherenkov emission and the typical BGO scintillation, can sort events into multiple timing kernels, best described by the Gaussian mixture models. The number of Cherenkov photons detected per event impacts directly the detector time resolution and signal rise time, which can later be used to improve the coincidence timing resolution. This work presents a simulation toolkit which applies multiple timing spreads on the coincident events and an image reconstruction that incorporates this information. A full cylindrical BGO-Cherenkov PET model was compared, in terms of contrast recovery and contrast-to-noise ratio, against an LYSO model with a time resolution of 213 ps. Two reconstruction approaches for the mixture kernels were tested: 1) mixture Gaussian and 2) decomposed simple Gaussian kernels. The decomposed model used the exact mixture component applied during the simulation. Images reconstructed using mixture kernels provided similar mean value and less noise than the decomposed. However, typically, more iterations were needed. Similarly, the LYSO model, with a single TOF kernel, converged faster than the BGO-Cherenkov with multiple kernels. The results indicate that the model complexity slows down convergence. However, due to the higher sensitivity, the contrast-to-noise ratio was 26.4% better for the BGO model.
Authors 6
-
University of Hull · University of Pennsylvania
Affiliation as printed
Department Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104 USA
PET Research Centre, Faculty of Health Sciences, University of Hull, Hull, U.K
Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
-
University of Vienna · European Organization for Nuclear Research
Affiliation as printed
University of Vienna, 1010 Vienna, Austria
European Organization for Nuclear Research, Geneva, Switzerland
University of Vienna, Vienna, Austria
-
S. Gundacker Aachen Department of Physics of Molecular Imaging Systems Institute for Experimental Molecular Imaging
University of Milano-Bicocca · European Organization for Nuclear Research · RWTH Aachen University
Affiliation as printed
Department of Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, 52062 Aachen, Germany
European Organization for Nuclear Research, Geneva, Switzerland
Institute for Experimental Molecular Imaging, RWTH Aachen University, Aachen, Germany
University of Milano-Bicocca, Milan, Italy
-
University of Milano-Bicocca · European Organization for Nuclear Research
Affiliation as printed
Physics Department, University of Milano-Bicocca, 20126 Milan, Italy
European Organization for Nuclear Research, Geneva, Switzerland
University of Milano-Bicocca, Milan, Italy
-
European Organization for Nuclear Research
Affiliation as printed
European Organization for Nuclear Research, 1211 Geneva, Switzerland
European Organization for Nuclear Research, Geneva, Switzerland
-
University of Milano-Bicocca · European Organization for Nuclear Research
Affiliation as printed
Physics Department, University of Milano-Bicocca, 20126 Milan, Italy
European Organization for Nuclear Research, Geneva, Switzerland
University of Milano-Bicocca, Milan, Italy
Cited by 54 stored of 54
Cited by patents worldwide 4 (Lens.org)
-
NUCLEAR MEDICINE DIAGNOSIS APPARATUS, DATA PROCESSING METHOD, AND PROGRAMEP4345506B1 2026-06-24 Active
-
NUCLEAR MEDICINE DIAGNOSTIC DEVICE, DATA PROCESSING METHOD, AND PROGRAMJP2024052415A 2024-04-11 Active
-
NUCLEAR MEDICINE DIAGNOSIS APPARATUS, DATA PROCESSING METHOD, AND PROGRAMEP4345506A1 2024-04-03 Active
-
NUCLEAR MEDICINE DIAGNOSTIC DEVICE, DATA PROCESSING METHOD, AND PROGRAMEP4345507A1 2024-04-03 Pending