A Coupled Two-Domain Approach for Transpiration Cooling
Notes on numerical fluid mechanics and multidisciplinary design, pp. 33–49
Abstract
Abstract Transpiration cooling is an innovative cooling concept where a coolant is injected through a porous ceramic matrix composite (CMC) material into a hot gas flow. This setting is modeled by a two-domain approach coupling two models for the hot gas domain and the porous medium to each other by coupling conditions imposed at the interface. For this purpose, appropriate coupling conditions, in particular accounting for local mass injection, are developed. To verify the feasibility of the two-domain approach numerical simulations in 3D are performed for two different application scenarios: a subsonic thrust chamber and a supersonic nozzle.
Authors 3
-
Affiliation as printed
(B) IGPM , RWTH Aachen University , Templergraben 55 , Aachen 52056 , Germany
IGPM, RWTH Aachen University, Aachen, Germany
-
Michael Rom Aachen
Affiliation as printed
IGPM, RWTH Aachen University, Aachen, Germany
-
Affiliation as printed
(B) IGPM , RWTH Aachen University , Templergraben 55 , Aachen 52056 , Germany
IGPM, RWTH Aachen University, Aachen, Germany
Cited by 7 stored of 7
7 results
No patents citing this paper on Lens.org (checked 2026-10-06).