Imaging of two samples with a single transmit/receive channel using coupled ceramic resonators for MR microscopy at 17.2 T
NMR in Biomedicine, vol. 33, pp. e4397
Abstract
In this paper we address the possibility to perform imaging of two samples within the same acquisition time using coupled ceramic resonators and one transmit/receive channel. We theoretically and experimentally compare the operation of our ceramic dual-resonator probe with a wire-wound solenoid probe, which is the standard probe used in ultrahigh-field magnetic resonance microscopy. We show that due to the low-loss ceramics used to fabricate the resonators, and a favorable distribution of the electric field within the conducting sample, a dual probe, which contains two samples, achieves an SNR enhancement by a factor close to the square root of 2 compared with a solenoid optimized for one sample.
Authors 12
-
Marine A.C. Moussu corresponding
Centre National de la Recherche Scientifique · Aix-Marseille Université · Institut Fresnel · Centrale Méditerranée
Affiliation as printed
Aix Marseille Univ, CNRS, Centrale Marseille, Institut Fresnel, 13013, Marseille, France Marseille France
Multiwave Imaging Marseille France
Aix Marseille Univ, CNRS, Centrale Marseille, Institut Fresnel, 13013, Marseille, France, Marseille, France
Multiwave Imaging, Marseille, France
-
Affiliation as printed
ITMO University Saint‐Petersburg Russia
ITMO University, Saint-Petersburg, Russia
-
Centre National de la Recherche Scientifique · Aix-Marseille Université · Institut Fresnel · Centrale Méditerranée
Affiliation as printed
Aix Marseille Univ, CNRS, Centrale Marseille, Institut Fresnel, 13013, Marseille, France Marseille France
Aix Marseille Univ, CNRS, Centrale Marseille, Institut Fresnel, 13013, Marseille, France, Marseille, France
-
Affiliation as printed
Université Catholique de Louvain Louvain‐la‐Neuve Belgium
Université Catholique de Louvain Louvain‐la‐Neuve Belgium
-
Centre National de la Recherche Scientifique · Aix-Marseille Université · Institut Fresnel · Centrale Méditerranée
Affiliation as printed
Aix Marseille Univ, CNRS, Centrale Marseille, Institut Fresnel, 13013, Marseille, France Marseille France
Aix Marseille Univ, CNRS, Centrale Marseille, Institut Fresnel, 13013, Marseille, France, Marseille, France
-
Affiliation as printed
Cavendish Laboratory University of Cambridge Cambridge UK
Cavendish Laboratory, University of Cambridge, Cambridge, UK
-
Affiliation as printed
ITMO University Saint‐Petersburg Russia
ITMO University, Saint-Petersburg, Russia
-
Centre National de la Recherche Scientifique · Aix-Marseille Université · Institut Fresnel · Centrale Méditerranée
Affiliation as printed
Aix Marseille Univ, CNRS, Centrale Marseille, Institut Fresnel, 13013, Marseille, France Marseille France
Aix Marseille Univ, CNRS, Centrale Marseille, Institut Fresnel, 13013, Marseille, France, Marseille, France
-
Affiliation as printed
Multiwave Imaging Marseille France
Multiwave Imaging, Marseille, France
-
Leiden University · Leiden University Medical Center
Affiliation as printed
Medical Center Leiden University Leiden the Netherlands
Medical Center, Leiden University, Leiden, the Netherlands
-
Affiliation as printed
ITMO University Saint‐Petersburg Russia
ITMO University, Saint-Petersburg, Russia
-
Commissariat à l'Énergie Atomique et aux Énergies Alternatives · CEA Paris-Saclay
Affiliation as printed
Neurospin, CEA, Gif‐sur‐Yvette, France Gif‐sur‐Yvette France
Neurospin, CEA, Gif-sur-Yvette, France, Gif-sur-Yvette, France
Cited by 9 stored of 9
9 results
No patents citing this paper on Lens.org (checked 2026-10-11).