7T MR Safety
Journal of Magnetic Resonance Imaging, vol. 53, pp. 333–346
Abstract
Magnetic resonance imaging and spectroscopy (MRI/MRS) at 7T represents an exciting advance in MR technology, with intriguing possibilities to enhance image spatial, spectral, and contrast resolution. To ensure the safe use of this technology while still harnessing its potential, clinical staff and researchers need to be cognizant of some safety concerns arising from the increased magnetic field strength and higher Larmor frequency. The higher static magnetic fields give rise to enhanced transient bioeffects and an increased risk of adverse incidents related to electrically conductive implants. Many technical challenges remain and the continuing rapid pace of development of 7T MRI/MRS is likely to present further challenges to ensuring safety of this technology in the years ahead. The recent regulatory clearance for clinical diagnostic imaging at 7T will likely increase the installed base of 7T systems, particularly in hospital environments with little prior ultrahigh-field MR experience. Informed risk/benefit analyses will be required, particularly where implant manufacturer-published 7T safety guidelines for implants are unavailable. On behalf of the International Society for Magnetic Resonance in Medicine, the aim of this article is to provide a reference document to assist institutions developing local institutional policies and procedures that are specific to the safe operation of 7T MRI/MRS. Details of current 7T technology and the physics underpinning its functionality are reviewed, with the aim of supporting efforts to expand the use of 7T MRI/MRS in both research and clinical environments. Current gaps in knowledge are also identified, where additional research and development are required. Level of Evidence 5 Technical Efficacy 2 J. MAGN. RESON. IMAGING 2021;53:333-346.
Authors 6
-
Andrew J Fagan corresponding
Affiliation as printed
Department of Radiology Mayo Clinic Rochester Minnesota USA
Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA
-
Andreas K. Bitz Aachen Faculty of Electrical Engineering and Information Technology FH Aachen ‐ University of Applied Sciences Aachen Germany Faculty of Electrical Engineering and Information Technology
Affiliation as printed
Faculty of Electrical Engineering and Information Technology FH Aachen ‐ University of Applied Sciences Aachen Germany
Faculty of Electrical Engineering and Information Technology, FH Aachen - University of Applied Sciences, Aachen, Germany
-
Sahlgrenska University Hospital · University of Gothenburg
Affiliation as printed
Department of Radiology University of Gothenburg, Sahlgrenska Academy, Sahlgrenska University Hospital Gothenburg Sweden
Department of Radiology, University of Gothenburg, Sahlgrenska Academy, Sahlgrenska University Hospital, Gothenburg, Sweden
-
NYU Langone Health · Center for Advanced Imaging Innovation and Research
Affiliation as printed
Center for Advanced Imaging Innovation and Research NYU Langone Medical Center New York New York USA
Center for Advanced Imaging Innovation and Research, NYU Langone Medical Center, New York, New York, USA
-
Affiliation as printed
Department of Radiology Brigham and Women's Hospital Boston Massachusetts USA
Department of Radiology, Brigham and Women's Hospital, Boston, Massachusetts, USA
-
University Medical Center Utrecht
Affiliation as printed
Department of Radiology UMC Utrecht Utrecht The Netherlands
Department of Radiology, UMC Utrecht, Utrecht, The Netherlands
Cited by 74 stored of 74
No patents citing this paper on Lens.org (checked 2026-10-06).