A

Drug Loading in Poly(butyl cyanoacrylate)-Based Polymeric Microbubbles

Molecular Pharmaceutics, vol. 17, pp. 2840–2848

Abstract

Microbubbles (MB) are routinely used ultrasound (US) contrast agents that have recently attracted increasing attention as stimuli-responsive drug delivery systems. To better understand MB-based drug delivery, we studied the role of drug hydrophobicity and molecular weight on MB loading, shelf-life stability, US properties, and drug release. Eight model drugs, varying in hydrophobicity and molecular weight, were loaded into the shell of poly(butyl cyanoacrylate) (PBCA) MB. In the case of drugs with progesterone as a common structural backbone (i.e., for corticosteroids), loading capacity and drug release correlated well with hydrophobicity and molecular weight. Conversely, when employing drugs with no structural similarity (i.e., four different fluorescent dyes), loading capacity and release did not correlate with hydrophobicity and molecular weight. All model drug-loaded MB formulations could be equally efficiently destroyed upon exposure to US. Together, these findings provide valuable insights on how the physicochemical properties of (model) drug molecules affect their loading and retention in and US-induced release from polymeric MB, thereby facilitating the development of drug-loaded MB formulations for US-triggered drug delivery.

Authors 7

  1. Universitätsklinikum Aachen · RWTH Aachen University

    Affiliation as printed

    Institute for Experimental Molecular Imaging, RWTH Aachen University Clinic, Aachen 52074, Germany

  2. Universitätsklinikum Aachen · RWTH Aachen University

    Affiliation as printed

    Institute for Experimental Molecular Imaging, RWTH Aachen University Clinic, Aachen 52074, Germany

  3. Universitätsklinikum Aachen · RWTH Aachen University

    Affiliation as printed

    Department of Intensive Care Medicine, Medical Faculty, RWTH Aachen University Clinic, Aachen 52074, Germany

    Institute for Experimental Molecular Imaging, RWTH Aachen University Clinic, Aachen 52074, Germany

  4. DWI – Leibniz Institute for Interactive Materials · RWTH Aachen University

    Affiliation as printed

    DWI—Leibniz Institute for Interactive Materials, RWTH Aachen University, Aachen 52074, Germany

  5. Universitätsklinikum Aachen · RWTH Aachen University

    Affiliation as printed

    Institute for Experimental Molecular Imaging, RWTH Aachen University Clinic, Aachen 52074, Germany

  6. Universitätsklinikum Aachen · RWTH Aachen University

    Affiliation as printed

    Institute for Experimental Molecular Imaging, RWTH Aachen University Clinic, Aachen 52074, Germany

  7. Universitätsklinikum Aachen · RWTH Aachen University

    Affiliation as printed

    Institute for Experimental Molecular Imaging, RWTH Aachen University Clinic, Aachen 52074, Germany

Cited by 35 stored of 37

No patents citing this paper on Lens.org (checked 2026-10-06).

References 33